Suppr超能文献

Self-tonometry in glaucoma.

作者信息

Tarkkanen Ahti, Ulfves Kristian, Ulfves Tuulikki

出版信息

Graefes Arch Clin Exp Ophthalmol. 2010 Nov;248(11):1679-81. doi: 10.1007/s00417-010-1421-y. Epub 2010 Jun 8.

Abstract
摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e5a8/2944952/8f2b12b1816e/417_2010_1421_Fig1_HTML.jpg

相似文献

1
Self-tonometry in glaucoma.
Graefes Arch Clin Exp Ophthalmol. 2010 Nov;248(11):1679-81. doi: 10.1007/s00417-010-1421-y. Epub 2010 Jun 8.
3
Self-tonometry as a complement in the investigation of glaucoma patients.
Acta Ophthalmol. 2016 Dec;94(8):788-792. doi: 10.1111/aos.13129. Epub 2016 May 26.
5
[Comparative characteristics of current tonometric methods].
Vestn Oftalmol. 2008 Sep-Oct;124(5):11-4.
6
ICare Pro: Age Dependent Effect of Central Corneal Thickness on Intraocular Pressure in Glaucoma and Ocular Hypertension Patients.
Curr Eye Res. 2020 Jun;45(6):668-674. doi: 10.1080/02713683.2019.1696977. Epub 2020 Jan 6.
7
[Eye-pressure tonometry in prevention of glaucoma].
Ophthalmologe. 1993 Dec;90(6):557-62.
9
Intraocular pressure assessment after laser in situ keratomileusis: a review.
Clin Exp Ophthalmol. 2012 Apr;40(3):295-304. doi: 10.1111/j.1442-9071.2011.02641.x. Epub 2011 Sep 2.
10
IOP Measurement and central corneal thickness.
Ophthalmology. 2012 Dec;119(12):2647-8; author reply 2648-9.e1. doi: 10.1016/j.ophtha.2012.07.034.

引用本文的文献

2
Can higher end tonometers be used interchangeably in routine clinical practice?
Indian J Ophthalmol. 2016 Feb;64(2):132-5. doi: 10.4103/0301-4738.179723.
4
Is 24-hour intraocular pressure monitoring necessary in glaucoma?
Semin Ophthalmol. 2013 May;28(3):157-64. doi: 10.3109/08820538.2013.771201.
5
Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects.
Graefes Arch Clin Exp Ophthalmol. 2012 Aug;250(8):1207-11. doi: 10.1007/s00417-011-1875-6.

本文引用的文献

1
Self-tonometry in glaucoma management--past, present and future.
Surv Ophthalmol. 2009 Jul-Aug;54(4):450-62. doi: 10.1016/j.survophthal.2009.04.006.
3
Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic.
Graefes Arch Clin Exp Ophthalmol. 2004 Jan;242(1):3-7. doi: 10.1007/s00417-003-0671-3. Epub 2003 Nov 21.
5
A new electromechanical method for measuring intraocular pressure.
Doc Ophthalmol. 1996;93(3):265-76. doi: 10.1007/BF02569066.
6
Miniature passive pressure transensor for implanting in the eye.
IEEE Trans Biomed Eng. 1967 Apr;14(2):74-83. doi: 10.1109/tbme.1967.4502474.
7
Home tonometry.
Am J Ophthalmol. 1973 Dec;76(6):929-32. doi: 10.1016/0002-9394(73)90084-6.
8
Self-tonometry to manage patients with glaucoma and apparently controlled intraocular pressure.
Arch Ophthalmol. 1987 Aug;105(8):1072-5. doi: 10.1001/archopht.1987.01060080074031.