全膝关节置换术中膝关节软组织对手术技术的敏感性。

Sensitivity of knee soft-tissues to surgical technique in total knee arthroplasty.

作者信息

Schirm Andreas C, Jeffcote Benjamin O, Nicholls Rochelle L, Jakob Hilaire, Kuster Markus S

机构信息

Klinik für Orthopaedische Chirurgie, Kantonsspital, St. Gallen, 9007, Switzerland.

出版信息

Knee. 2011 Jun;18(3):180-4. doi: 10.1016/j.knee.2010.05.005. Epub 2010 Jun 12.

Abstract

Restricted range of motion and excessive laxity are both potential complications of total knee arthroplasty (TKA). During TKA surgery, the surgeon is frequently faced with the question of how tightly to implant the prosthesis. The most common method of altering implantation tightness is to vary the thickness of the polyethylene inlay after the bone cuts have been made and the trial components inserted. We have sought to quantify how altering the polyethylene thickness may affect post-operative soft tissue tension for a range of prosthetic designs. Four different prosthetic designs were implanted into fresh-frozen cadaveric knee joints. All four designs were implanted in the standard manner, with a 100 Newton distraction force used to set soft tissue balance. The tibiofemoral force was then recorded at 15° intervals throughout the passive flexion range. After the standard implantation of each prosthesis, the tibial component was raised or lowered to mimic increasing and decreasing the polyethylene thickness by 2mm and the force measurements repeated. Tibiofemoral force in extension correlated with implantation tightness for all prosthesis designs. Between 15° and 90° of knee flexion, all four designs were insensitive to changes in implantation tightness. Beyond 90° the effect was more notable in rotating platform mobile-bearing and cruciate-retaining prostheses than in posterior-stabilised mobile-bearing designs. The findings of this research may be useful in assisting surgical decision-making during the implantation of TKA prostheses.

摘要

活动范围受限和过度松弛都是全膝关节置换术(TKA)的潜在并发症。在TKA手术过程中,外科医生经常面临假体植入多紧的问题。改变植入紧密度最常见的方法是在完成截骨并插入试验组件后改变聚乙烯内衬的厚度。我们试图量化改变聚乙烯厚度对一系列假体设计的术后软组织张力有何影响。将四种不同的假体设计植入新鲜冷冻的尸体膝关节。所有四种设计均以标准方式植入,使用100牛顿的牵张力来设定软组织平衡。然后在整个被动屈曲范围内每隔15°记录胫股力。在每种假体进行标准植入后,升高或降低胫骨组件以模拟聚乙烯厚度增加或减少2毫米,并重复力的测量。所有假体设计在伸直位时的胫股力与植入紧密度相关。在膝关节屈曲15°至90°之间,所有四种设计对植入紧密度的变化均不敏感。超过90°后,旋转平台活动轴承和保留交叉韧带的假体比后稳定活动轴承设计的影响更显著。本研究结果可能有助于在TKA假体植入过程中辅助手术决策。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验