Suppr超能文献

[使用注射器系统对猪眼白内障人工晶状体植入术后透明角膜切口磨损情况的评估]

[Evaluation of post intraocular lens implantation detrition of clear corneal incisions using an injector system in porcine eyes].

作者信息

Usui Takahiro, Nishimura Eiichi, Soda Mitsutaka, Yaguchi Shigeo, Oniki Hiroaki, Nakano Kiyoko

机构信息

Department of Ophthalmology, Showa University Fujigaoka Hospital, Japan.

出版信息

Nippon Ganka Gakkai Zasshi. 2010 May;114(5):429-35.

Abstract

PURPOSE

To evaluate the detrition of clear corneal incisions (CCIs) after intraocular lens (IOL) implantation using an injector system in porcine eyes.

METHODS

Group A: after CCIs were performed with 1.8, 2.0, 2.2, 2.4, and 2.65 mm wide slit knives, a Y-60 H (HOYA) IOL was implanted in the anterior chamber using an injector system. Group B: after CCIs were performed with 2.4, 2.65, 2.8, 3.0, and 3.2 mm wide slit knives, a PY-60 R (HOYA) IOL was implanted in the anterior chamber using an injector system. Group C: after CCIs were performed with 2.8, 3.0, 3.2, 3.4 mm wide slit knives, a SN 60 AT (Alcon) IOL was implanted in the anterior chamber using an injector system.

CONTROL

CCIs were performed with 3.0 mm wide slit knives. Each group used five porcine eyes for each slit knife (Group A 25 eyes; Group B 25 eyes; Group C 20 eyes; CONTROL 5 eyes). The detrition of the CCIs was evaluated on three different aspects using a scanning electron microscope: a) external expansion at both edges of CCIs; b) rupture of the collagen fibers; c) expansion between the collagen fibers. Aspects a, b and c were given a score of 0, 1, and 2, respectively, and the total points were compared statistically between test and control groups.

RESULTS

The degree of CCIs detrition was significantly reduced in CCIs with a width of more than 2.4 mm of CCIs width in Group A, more than 3.0 mm in Group B, and more than 3.2 mm in Group C.

CONCLUSIONS

Minimizing the detrition of corneal incisions after IOL implantation needs a larger than the recommended width of corneal incision.

摘要

目的

使用注射器系统在猪眼中评估人工晶状体(IOL)植入术后透明角膜切口(CCI)的磨损情况。

方法

A组:使用1.8、2.0、2.2、2.4和2.65毫米宽的裂隙刀制作CCI后,使用注射器系统将Y-60 H(豪雅)人工晶状体植入前房。B组:使用2.4、2.65、2.8、3.0和3.2毫米宽的裂隙刀制作CCI后,使用注射器系统将PY-60 R(豪雅)人工晶状体植入前房。C组:使用2.8、3.0、3.2、3.4毫米宽的裂隙刀制作CCI后,使用注射器系统将SN 60 AT(爱尔康)人工晶状体植入前房。

对照组

使用3.0毫米宽的裂隙刀制作CCI。每组每种裂隙刀使用5只猪眼(A组25只眼;B组25只眼;C组20只眼;对照组5只眼)。使用扫描电子显微镜从三个不同方面评估CCI的磨损情况:a)CCI两边的外部扩张;b)胶原纤维的断裂;c)胶原纤维之间的扩张。方面a、b和c分别给予0、1和2分,并对试验组和对照组的总分进行统计学比较。

结果

A组中CCI宽度大于2.4毫米、B组中大于3.0毫米、C组中大于3.2毫米的CCI,其磨损程度显著降低。

结论

将人工晶状体植入术后角膜切口的磨损降至最低需要比推荐的角膜切口宽度更大的切口宽度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验