PURPOSE

To evaluate the impermeability to blood of the modified E-vita open plus hybrid stent-graft in animal experiments and initial clinical applications in the replacement of the ascending aorta and aortic arch combined with antegrade stent-grafting of the descending aorta.

METHODS

In 3 acute pig experiments, a tightly woven hybrid stent-graft (18 x 50-mm) was implanted in the descending aorta. Blood loss was measured after clamp release in fully heparinized animals by wrapping the aortic segment in a polyethylene bag. For histological examination, 12-mm-diameter stent-grafts were interposed in the abdominal aorta of 6 minipigs. The animals were sacrificed and studied after 3, 6, and 9 weeks. Between October 2008 and October 2009, 9 patients were treated for 6 type I dissections and 3 thoracic aortic aneurysms using the new prosthesis. Blood loss and blood replacement were evaluated.

RESULTS

Mean blood loss under heparinization was 35+/-4 mL/min in the animal model. Histological examination of the explanted grafts demonstrated buildup of neointima. In the clinical cases, the mean blood loss within the first 24 hours was 489 mL; no re-exploration for bleeding was required. During a 6-month follow-up, no thrombus formation was seen within the vascular graft and no embolic event occurred.

CONCLUSION

The new low-porosity hybrid prosthesis proved to be absolutely tight in animal experiments; histological examination demonstrated endothelial cell ingrowth with a trend to hyperplasia in this small-diameter graft. These results were confirmed in the clinical cases by the extremely minimal blood loss and an uneventful course.

摘要

目的

在动物实验中评估改良的 E-vita open plus 杂交支架移植物的血液渗透性,并在升主动脉和主动脉弓置换以及顺行支架置入治疗降主动脉的初步临床应用中进行评估。

方法

在 3 项急性猪实验中,将紧密编织的杂交支架(18 x 50mm)植入降主动脉。在充分肝素化的动物中,通过用聚乙烯袋包裹主动脉段来测量夹闭释放后的出血量。为了进行组织学检查,在 6 只小型猪的腹主动脉中插入 12mm 直径的支架。动物在 3、6 和 9 周后被处死并进行研究。2008 年 10 月至 2009 年 10 月,使用新假体治疗了 9 例 1 型夹层和 3 例胸主动脉瘤。评估了出血量和血液置换。

结果

动物模型中肝素化下的平均失血量为 35+/-4mL/min。对取出的移植物进行组织学检查显示新生内膜形成。在临床病例中,第 1 个 24 小时内的平均失血量为 489mL,无需再次探查出血。在 6 个月的随访期间,血管移植物内未发现血栓形成,也未发生栓塞事件。

结论

新型低孔隙率杂交假体在动物实验中被证明是完全紧密的;组织学检查显示内皮细胞向内生长,在这个小直径的移植物中有增生的趋势。这些结果在临床病例中得到了证实,即出血量极低且无并发症发生。