Suppr超能文献

基于高速视频内窥镜记录的声带振动不对称性的自动测量。

Automated measurement of vocal fold vibratory asymmetry from high-speed videoendoscopy recordings.

机构信息

Massachusetts General Hospital, Center for Laryngeal Surgery and Voice Rehabilitation, 1 Bowdoin Square, 11th Floor, Boston, MA 02114, USA.

出版信息

J Speech Lang Hear Res. 2011 Feb;54(1):47-54. doi: 10.1044/1092-4388(2010/10-0026). Epub 2010 Aug 10.

Abstract

PURPOSE

In prior work, a manually derived measure of vocal fold vibratory phase asymmetry correlated to varying degrees with visual judgments made from laryngeal high-speed videoendoscopy (HSV) recordings. This investigation extended this work by establishing an automated HSV-based framework to quantify 3 categories of vocal fold vibratory asymmetry.

METHOD

HSV-based analysis provided for cycle-to-cycle estimates of left-right phase asymmetry, left-right amplitude asymmetry, and axis shift during glottal closure for 52 speakers with no vocal pathology producing comfortable and pressed phonation. An initial cross-validation of the automated left-right phase asymmetry measure was performed by correlating the measure with other objective and subjective assessments of phase asymmetry.

RESULTS

Vocal fold vibratory asymmetry was exhibited to a similar extent in both comfortable and pressed phonations. The automated measure of left-right phase asymmetry strongly correlated with manually derived measures and moderately correlated with visual-perceptual ratings. Correlations with the visual-perceptual ratings remained relatively consistent as the automated measure was derived from kymograms taken at different glottal locations.

CONCLUSIONS

An automated HSV-based framework for the quantification of vocal fold vibratory asymmetry was developed and initially validated. This framework serves as a platform for investigating relationships between vocal fold tissue motion and acoustic measures of voice function.

摘要

目的

在先前的工作中,手动得出的声带振动相位不对称性测量值与从声带高速视频内窥镜(HSV)记录中做出的视觉判断相关程度不同。本研究通过建立基于 HSV 的自动化框架来量化 3 类声带振动不对称性,扩展了这项工作。

方法

基于 HSV 的分析提供了在声带闭合期间的左右相位不对称性、左右幅度不对称性和轴偏移的逐周期估计,用于 52 名没有发声病理学的说话者产生舒适和加压发声。通过将该测量值与相位不对称性的其他客观和主观评估进行相关分析,对自动左右相位不对称性测量值进行了初步的交叉验证。

结果

在舒适和加压发声中,声带振动不对称性表现出相似的程度。左右相位不对称的自动测量值与手动测量值具有很强的相关性,与视觉感知评分具有中度相关性。当自动测量值是从不同声门位置的振谱图中得出时,与视觉感知评分的相关性仍然相对一致。

结论

开发并初步验证了一种基于 HSV 的声带振动不对称性定量分析的自动化框架。该框架为研究声带组织运动与嗓音功能声学测量之间的关系提供了一个平台。

相似文献

6
Phase asymmetries in normophonic speakers: visual judgments and objective findings.正常语音者的相位不对称性:视觉判断与客观发现。
Am J Speech Lang Pathol. 2008 Nov;17(4):367-76. doi: 10.1044/1058-0360(2008/07-0059). Epub 2008 Oct 7.
10
Vocal Fold Vibratory Changes Following Surgical Intervention.手术干预后的声带振动变化
J Voice. 2016 Mar;30(2):224-7. doi: 10.1016/j.jvoice.2015.03.016. Epub 2015 May 29.

引用本文的文献

本文引用的文献

2
Phase asymmetries in normophonic speakers: visual judgments and objective findings.正常语音者的相位不对称性:视觉判断与客观发现。
Am J Speech Lang Pathol. 2008 Nov;17(4):367-76. doi: 10.1044/1058-0360(2008/07-0059). Epub 2008 Oct 7.
5
Phonovibrogram visualization of entire vocal fold dynamics.整个声带动态的声振图可视化
Laryngoscope. 2008 Apr;118(4):753-8. doi: 10.1097/MLG.0b013e318161f9e1.
9
Videokymography in voice disorders: what to look for?嗓音障碍中的视频动态镜检查:应关注什么?
Ann Otol Rhinol Laryngol. 2007 Mar;116(3):172-80. doi: 10.1177/000348940711600303.