Suppr超能文献

串联飞行时间(TOF/TOF)质谱分析与蛋白质组学

Tandem Time-of-Flight (TOF/TOF) Mass Spectrometry and Proteomics.

作者信息

Cotter Robert J, Iltchenko Serguei, Wang Dongxia, Gundry Rebekah

机构信息

Middle Atlantic Mass Spectrometry Laboratory, Johns Hopkins University School of Medicine (Baltimore, MD 21205, U.S.A.).

出版信息

J Mass Spectrom Soc Jpn. 2005 Jan 5;53(1):7-17. doi: 10.5702/massspec.53.7.

Abstract

A dual reflectron tandem time-of-flight (TOF/TOF) mass spectrometer reported in 1993 gave rise to the invention and development of the curved-field reflectron (CFR) for focusing product ions. The CFR is used in this case as the second mass analyzer in a tandem instrument (based on the Kratos AXIMA CFR) in which the first mass analyzer is a linear TOF that focuses ions by pulsed extraction. Because ions can be focused over a broad range of kinetic energies, deceleration of precursor ions and/or reacceleration of product ions is not required. Thus, product ions produced by post-source processes (laser induced dissociation or LID, metastable decomposition and opportunistic collisions) are recorded in the product ion mass spectra at the same times as their isomass ions produced by collision induced dissociation (CID). In general both LID and CID product ion mass spectra are very similar, producing primarily b-series and y-series ions, though there is some preference for fragmentation at weaker bonds such as those at proline or aspartic acid residues. The tandem mass spectrometer has been used to determine the acetylation sites for a histone acetyl transferase (HAT) protein. A novel and improved method for derivatizing tryptic fragments by N-terminal sulfonation produces almost exclusively y-series ions, and has been used to determine protein ubiquitination. The tandem mass spectrometer has also been used to identify potential biomarkers associated with heart failure, in particular that fraction containing albumin that is generally removed from serum samples to permit protein biomarker analysis. Analysis of the unfractionated serum, the albuminome, and the depleted serum is also carried out using surface-enhanced laser desorption/ionization (SELDI) and the high molecular weight proteins are monitored by using a Comet macromizer TOF mass spectrometer with a very high mass cryocooled detector.

摘要

1993年报道的双反射器串联飞行时间(TOF/TOF)质谱仪推动了用于聚焦产物离子的弯曲场反射器(CFR)的发明与发展。在这种情况下,CFR用作串联仪器(基于Kratos AXIMA CFR)中的第二个质量分析器,其中第一个质量分析器是通过脉冲提取聚焦离子的线性TOF。由于离子可以在很宽的动能范围内聚焦,因此不需要对前体离子进行减速和/或对产物离子进行再加速。因此,源后过程(激光诱导解离或LID、亚稳分解和机会性碰撞)产生的产物离子与碰撞诱导解离(CID)产生的等质量离子同时记录在产物离子质谱中。一般来说,LID和CID产物离子质谱非常相似,主要产生b系列和y系列离子,不过在脯氨酸或天冬氨酸残基等较弱键处的碎片化有一定偏好。该串联质谱仪已用于确定组蛋白乙酰转移酶(HAT)蛋白的乙酰化位点。一种通过N端磺化衍生胰蛋白酶片段的新颖且改进的方法几乎只产生y系列离子,并已用于确定蛋白质的泛素化。该串联质谱仪还用于鉴定与心力衰竭相关的潜在生物标志物,特别是血清样本中通常会去除的含白蛋白部分,以便进行蛋白质生物标志物分析。还使用表面增强激光解吸/电离(SELDI)对未分级血清、白蛋白组和去除白蛋白的血清进行分析,并使用配备非常高质量低温冷却检测器的Comet macromizer TOF质谱仪监测高分子量蛋白质。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a1c0/2922030/b24e137ea52f/nihms178245f1.jpg

相似文献

2
Tandem time-of-flight (TOF/TOF) mass spectrometry and the curved-field reflectron.串联飞行时间(TOF/TOF)质谱仪与弯曲场反射器。
J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Aug;855(1):2-13. doi: 10.1016/j.jchromb.2007.01.009. Epub 2007 Jan 13.

引用本文的文献

1
Proteomics of the heart.心脏蛋白质组学。
Physiol Rev. 2024 Jul 1;104(3):931-982. doi: 10.1152/physrev.00026.2023. Epub 2024 Feb 1.
3
Proteomic identification of protein ubiquitination events.蛋白质泛素化事件的蛋白质组学鉴定。
Biotechnol Genet Eng Rev. 2013;29(1):73-109. doi: 10.1080/02648725.2013.801232.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验