Suppr超能文献

口腔黏膜脱落细胞学检查:两种采集方法的比较

Exfoliative cytology of the oral mucosa: comparison of two collection methods.

作者信息

Queiroz Juliana Brusadin, Lima Celina Faig, Burim Rafael Augusto, Brandao Adriana Aigotti Haberbeck, Cabral Luiz Antonio Guimaraes, Almeida Janete Dias

机构信息

Oral Biopathology, Sao Jose dos Campos Dental School, Sao Paulo State University, SP, Brazil.

出版信息

Gen Dent. 2010 Sep-Oct;58(5):e196-9.

Abstract

This study compared the sampling efficacy of a cytobrush and metal spatula for exfoliative cytology of the oral mucosa. Thirty students with no detectable oral alterations upon clinical examination were submitted to exfoliative cytology of the lateral border of the tongue, using a metal spatula on the left side and a cytobrush on the right side. The smears were stained using the Papanicolaou technique and evaluated for cellularity, cell type, cell distribution, homogeneity, and cellular distortion, as well as the presence of mucus, inflammatory infiltrate, and hemorrhage. A statistical test (Z-test) with a 95% confidence interval (CI) showed a significant difference between the metal spatula and cytobrush in terms of cellularity (p = 0.02) and homogeneity (p = 0.01). No difference between the two methods was observed regarding cell type (p = 0.4, Z-test) or cell distribution for the 95% confidence interval (p = 0.2, Fisher's test). Cell distortion and the presence of mucus were observed in five cases that used the metal spatula and in two cases that used the cytobrush. No hemorrhage or inflammatory infiltrate was detected in any of the slides. Based on the results of this study, the cytobrush produced qualitatively better smears in terms of cellularity and homogeneity compared to the metal spatula.

摘要

本研究比较了细胞刷和金属刮匙在口腔黏膜脱落细胞学检查中的采样效果。对30名临床检查未发现口腔病变的学生进行舌侧缘脱落细胞学检查,左侧使用金属刮匙,右侧使用细胞刷。涂片采用巴氏染色法染色,并对细胞数量、细胞类型、细胞分布、均匀性、细胞变形以及黏液、炎性浸润和出血的存在情况进行评估。采用95%置信区间(CI)的统计检验(Z检验)显示,金属刮匙和细胞刷在细胞数量(p = 0.02)和均匀性(p = 0.01)方面存在显著差异。两种方法在细胞类型(p = 0.4,Z检验)或95%置信区间的细胞分布(p = 0.2,Fisher检验)方面未观察到差异。在使用金属刮匙的5例和使用细胞刷的2例中观察到细胞变形和黏液存在。在任何一张载玻片中均未检测到出血或炎性浸润。基于本研究结果,与金属刮匙相比,细胞刷在细胞数量和均匀性方面产生的涂片质量更好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验