Berardinelli S P, Moyer E S, Hall R C
Department of Health and Human Services, National Institute for Occupational Safety and Health, Morgantown, WV 26505-2888.
Am Ind Hyg Assoc J. 1990 Nov;51(11):595-600. doi: 10.1080/15298669091370176.
An automated permeation test system was developed to collect permeation data. Three test specimens were evaluated simultaneously versus a challenge gas. The study evaluated chemical protective clothing garment materials for use by emergency response personnel confronted by ammonia or ethylene oxide in the gas phase. A total of 13 encapsulating suit materials and 2 glove materials were tested. Surgical latex material is not recommended for use in handling ammonia or ethylene oxide; other materials offer much greater protection.
开发了一种自动渗透测试系统来收集渗透数据。三个测试样本同时针对一种挑战气体进行评估。该研究评估了应急响应人员在气相中遇到氨或环氧乙烷时使用的化学防护服服装材料。总共测试了13种密封套装材料和2种手套材料。不建议使用外科乳胶材料来处理氨或环氧乙烷;其他材料提供了更好的防护。