OBJECTIVES

To describe second-hand smoke in the hospitals of the Catalan Network for Smoke-free Hospitals using Particulate Matter (PM(2.5)) and to assess the association between second-hand smoke exposure in main entrances (outdoors) and halls and between PM(2.5) and airborne nicotine concentrations.

METHODS

Cross-sectional study carried out in 2009 in the 53 hospitals affiliated with the network. We measured PM(2.5) (μg/m(3)) in all hospitals and measured airborne nicotine concentrations (μg/m(3)) in a subsample of 11 hospitals. For each assessment, we measured nine locations within the hospitals, computing medians, means, geometric means, interquartile ranges (IQRs), and 95% confidence intervals (CI) of the means and the geometric means. Further, we used Spearman's linear correlation coefficient r(sp)) to explore the association between PM(2.5) concentrations in halls and main entrances and between PM(2.5) and nicotine concentrations.

RESULTS

The overall median of the 429 PM(2.5) measurements was 12.48 μg/m(3) (IQR: 8.84-19.76 μg/m(3)). The most exposed locations were outdoor smoking points (16.64 μg/m(3)), cafeterias (14.82 μg/m(3)), and main entrances (14.04 μg/m(3)); dressing rooms were the least exposed (6.76 μg/m(3)). PM(2.5) concentrations in halls were positively correlated with those in main entrances (r(sp)=0.591, 95% CI: 0.377-0.745), as were PM(2.5) values and nicotine concentrations (r(sp)=0.644, 95% CI: 0.357-0.820).

CONCLUSIONS

Second-hand smoke levels in hospitals were low in most locations, with the highest levels observed in outdoor locations where smoking is allowed (smoking points and entrances). Smoking in main entrances was associated with increased second-hand smoke levels in halls. Use of PM(2.5) to evaluate second-hand smoke is feasible and shows a good correlation with airborne nicotine values.

摘要

目的

使用 PM(2.5) 描述加泰罗尼亚无烟医院网络中医院的二手烟,并评估主入口(室外)和大厅中二手烟暴露与 PM(2.5) 和空气传播尼古丁浓度之间的关联。

方法

这是 2009 年在网络中 53 家附属医院进行的一项横断面研究。我们测量了所有医院的 PM(2.5)(μg/m(3)),并在 11 家医院的样本中测量了空气传播尼古丁浓度(μg/m(3))。对于每次评估,我们在医院内测量了 9 个位置,计算了中位数、平均值、几何平均值、四分位间距 (IQR) 和平均值和几何平均值的 95%置信区间 (CI)。此外,我们使用 Spearman 线性相关系数 r(sp)) 来探索大厅和主入口处 PM(2.5)浓度之间以及 PM(2.5)与尼古丁浓度之间的关联。

结果

429 次 PM(2.5)测量的总体中位数为 12.48μg/m(3)(IQR:8.84-19.76μg/m(3))。暴露最严重的地点是室外吸烟点(16.64μg/m(3))、咖啡厅(14.82μg/m(3))和主入口(14.04μg/m(3));更衣室的暴露最少(6.76μg/m(3))。大厅中的 PM(2.5)浓度与主入口处的浓度呈正相关(r(sp)=0.591,95%CI:0.377-0.745),PM(2.5)值与尼古丁浓度也呈正相关(r(sp)=0.644,95%CI:0.357-0.820)。

结论

大多数地点的医院内二手烟水平较低,在允许吸烟的室外地点(吸烟点和入口处)水平最高。主入口处的吸烟与大厅中二手烟水平的增加有关。使用 PM(2.5)评估二手烟是可行的,并且与空气传播尼古丁值具有良好的相关性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验