Suppr超能文献

颅测量的准确性和可靠性的侧位头颅测量和 3D 测量的 CBCT 扫描。

Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans.

机构信息

Department of Orthodontics and Pediatric Dentistry, The University of Michigan, Ann Arbor, USA.

出版信息

Angle Orthod. 2011 Jan;81(1):26-35. doi: 10.2319/032210-166.1.

Abstract

OBJECTIVE

To compare the accuracy of craniometric measurements made on lateral cephalograms and on cone beam computed tomography (CBCT) images.

MATERIALS AND METHODS

Ten fiducial markers were placed on known craniometric landmarks of 25 dry skulls with stable occlusions. CBCT scans and conventional lateral headfilms subsequently were taken of each skull. Direct craniometric measurements were compared with CBCT measurements and with cephalometric measurements using repeated measures analysis of variance (ANOVA). All measurements were repeated within a 1-month interval, and intraclass correlations were calculated.

RESULTS

No statistically significant difference was noted between CBCT measurements and direct craniometric measurements (mean difference, 0.1 mm). All cephalometric measurements were significantly different statistically from direct craniometric measurements (mean difference, 5 mm). Significant variations among measurements were noted. Some measurements were larger on the lateral cephalogram and some were smaller, but a pattern could be observed: midsagittal measurements were enlarged uniformly, and Co-Gn was changed only slightly; Co-A was always smaller.

CONCLUSION

CBCT craniometric measurements are accurate to a subvoxel size and potentially can be used as a quantitative orthodontic diagnostic tool. Two-dimensional cephalometric norms cannot be readily used for three-dimensional measurements because of differences in measurement accuracy between the two exams.

摘要

目的

比较头颅测量值在侧位头颅片和锥形束 CT(CBCT)图像上的准确性。

材料和方法

将 10 个基准标记放置在 25 个具有稳定咬合的干颅骨的已知头颅测量标志上。随后对每个颅骨进行 CBCT 扫描和常规的侧位头颅片。直接头颅测量值与 CBCT 测量值和使用重复测量方差分析(ANOVA)的头影测量值进行比较。所有测量值在 1 个月的间隔内重复测量,并计算组内相关系数。

结果

CBCT 测量值与直接头颅测量值之间没有统计学上的显著差异(平均差异 0.1mm)。所有头影测量值与直接头颅测量值均存在统计学上的显著差异(平均差异 5mm)。测量值之间存在显著差异。有些测量值在侧位头颅片上较大,有些则较小,但可以观察到一种模式:正中矢状面测量值均匀放大,Co-Gn 仅略有变化;Co-A 总是较小。

结论

CBCT 头颅测量值的准确性达到亚像素大小,可作为一种定量正畸诊断工具。二维头影测量标准不能直接用于三维测量,因为两种检查的测量精度存在差异。

相似文献

引用本文的文献

本文引用的文献

1
Working with DICOM craniofacial images.处理DICOM颅面图像。
Am J Orthod Dentofacial Orthop. 2009 Sep;136(3):460-70. doi: 10.1016/j.ajodo.2009.04.016.
2
Accuracy of reconstructed images from cone-beam computed tomography scans.锥形束计算机断层扫描重建图像的准确性。
Am J Orthod Dentofacial Orthop. 2009 Aug;136(2):156.e1-6; discussion 156-7. doi: 10.1016/j.ajodo.2009.04.006.
3
Reliability and accuracy of cone-beam computed tomography dental measurements.锥形束计算机断层扫描牙科测量的可靠性和准确性。
Am J Orthod Dentofacial Orthop. 2009 Jul;136(1):19-25; discussion 25-8. doi: 10.1016/j.ajodo.2007.09.016.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验