Damstra Janalt, Fourie Zacharias, Ren Yijin
Department of Orthodontics, University Medical Center Groningen, University of Groningen, The Netherlands.
Br J Oral Maxillofac Surg. 2011 Jul;49(5):392-5. doi: 10.1016/j.bjoms.2010.06.006. Epub 2010 Jul 7.
The aim of this study was to compare two- and three-dimensional cephalometric values by using a three-dimensional analysis based on the midsagittal plane. Spherical metal markers were fixed on to the anatomical landmarks of 10 human skulls, which were examined radiographically with conventional lateral cephalograms and cone-beam computed tomographic (CBCT) scans. Preprogrammed analyses calculated the 18 angular and linear two- and three-dimensional cephalometric values. An error study was made to assess the accuracy and reliability of the methods used. Both sets of values were compared using Wilcoxon's signed-rank test. Probabilities of less than 0.05 were accepted as significant. Reliability of the measurements was assessed by intraclass correlation coefficients (ICC) based on absolute agreement. The method error (ME) was tiny (mean ME<0.61 measuring unit) and reliable (ICC>0.97). Comparison of the two- and three-dimensional measurements showed that that they were reliable (ICC>0.88) and that there were no significant differences (P=0.41-1.00). The values from the cephalometric analyses were comparable and interchangeable when using the midsagittal three-dimensional approach as described.
本研究的目的是通过基于正中矢状面的三维分析来比较二维和三维头影测量值。将球形金属标记物固定在10个人类颅骨的解剖标志点上,然后使用传统的侧位头影测量X线片和锥形束计算机断层扫描(CBCT)对其进行影像学检查。预先设定的分析计算了18个角度和线性的二维及三维头影测量值。进行了误差研究以评估所使用方法的准确性和可靠性。使用Wilcoxon符号秩检验对两组值进行比较。概率小于0.05被认为具有显著性。基于绝对一致性,通过组内相关系数(ICC)评估测量的可靠性。方法误差(ME)很小(平均ME<0.61测量单位)且可靠(ICC>0.97)。二维和三维测量的比较表明它们是可靠的(ICC>0.88),并且没有显著差异(P = 0.41 - 1.00)。当使用所述的正中矢状面三维方法时,头影测量分析得到的值具有可比性且可互换。