Validity and reliability of the Myotest accelerometric system for the assessment of vertical jump height.

机构信息

Neuromuscular Research Laboratory, Schulthess Clinic, Zurich, Switzerland.

出版信息

J Strength Cond Res. 2010 Nov;24(11):3186-93. doi: 10.1519/JSC.0b013e3181d8595c.

Abstract

The aim of the present study was to verify the validity and reliability of the Myotest accelerometric system (Myotest SA, Sion, Switzerland) for the assessment of vertical jump height. Forty-four male basketball players (age range: 9-25 years) performed series of squat, countermovement and repeated jumps during 2 identical test sessions separated by 2-15 days. Flight height was simultaneously quantified with the Myotest system and validated photoelectric cells (Optojump). Two calculation methods were used to estimate the jump height from Myotest recordings: flight time (Myotest-T) and vertical takeoff velocity (Myotest-V). Concurrent validity was investigated comparing Myotest-T and Myotest-V to the criterion method (Optojump), and test-retest reliability was also examined. As regards validity, Myotest-T overestimated jumping height compared to Optojump (p < 0.001) with a systematic bias of approximately 7 cm, even though random errors were low (2.7 cm) and intraclass correlation coefficients (ICCs) where high (>0.98), that is, excellent validity. Myotest-V overestimated jumping height compared to Optojump (p < 0.001), with high random errors (>12 cm), high limits of agreement ratios (>36%), and low ICCs (<0.75), that is, poor validity. As regards reliability, Myotest-T showed high ICCs (range: 0.92-0.96), whereas Myotest-V showed low ICCs (range: 0.56-0.89), and high random errors (>9 cm). In conclusion, Myotest-T is a valid and reliable method for the assessment of vertical jump height, and its use is legitimate for field-based evaluations, whereas Myotest-V is neither valid nor reliable.

摘要

本研究旨在验证 Myotest 加速计系统(Myotest SA,Sion,瑞士)评估垂直跳跃高度的有效性和可靠性。44 名男性篮球运动员(年龄范围:9-25 岁)在 2 次相同的测试中完成了一系列深蹲、反跳和重复跳跃,两次测试之间间隔 2-15 天。飞行高度同时用 Myotest 系统和光电传感器(Optojump)进行量化。使用两种计算方法从 Myotest 记录中估算跳跃高度:飞行时间(Myotest-T)和垂直起飞速度(Myotest-V)。通过比较 Myotest-T 和 Myotest-V 与标准方法(Optojump),研究了同时效度,还检查了测试-再测试可靠性。就有效性而言,与 Optojump 相比,Myotest-T 高估了跳跃高度(p<0.001),系统偏差约为 7 厘米,尽管随机误差较低(2.7 厘米),组内相关系数(ICC)较高(>0.98),即具有极好的有效性。与 Optojump 相比,Myotest-V 高估了跳跃高度(p<0.001),随机误差较大(>12 厘米),协议界限比(>36%)较高,ICC 较低(<0.75),即有效性较差。就可靠性而言,Myotest-T 显示出较高的 ICC(范围:0.92-0.96),而 Myotest-V 显示出较低的 ICC(范围:0.56-0.89)和较高的随机误差(>9 厘米)。总之,Myotest-T 是评估垂直跳跃高度的有效且可靠的方法,其在现场评估中的使用是合法的,而 Myotest-V 既无效也不可靠。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验