通过视频密度测定法评估最大心肌血流时平均通过时间的可重复性。

Reproducibility of mean transit time for maximal myocardial flow assessment by videodensitometry.

作者信息

Pijls N H, Uijen G J, Pijnenburg T, van Leeuwen K, Aengevaeren W R, Barth J D, den Arend J, Hoevelaken A, van der Werf T

机构信息

Department of Cardiology, St. Radboud Hospital, University of Nijmegen, The Netherlands.

出版信息

Int J Card Imaging. 1990;6(2):101-8. doi: 10.1007/BF02398893.

Abstract

In the assessment of myocardial perfusion by ECG-triggered digital radiography, time parameters are calculated from the time density curve (TDC) and related to blood flow. Recently we developed a method which uses mean transit time (Tmn) as time parameter, and which is in accordance with the original principles of indicator dilution theory. In this approach, variability in vascular volume is excluded and Tmn-1, determined at maximal hyperemia, showed an excellent correlation with maximal flow in animal validation studies. For calculation of Tmn, however, a large part of the descending limb of the TDC has to be known for reliable extrapolation, and especially this part of the curve is subject to variability in image quality in man. Therefore we tested reproducibility of Tmn in 30 arteries in 20 patients. Tmn was derived from the TDCs, obtained from paired studies under identical circumstances with an interval of 10 minutes. Satisfactory images could be obtained in all but one patient. Image processing was performed in an identical way in the paired studies. Reproducibility proved to be excellent for all three coronary arteries. The absolute value of the relative differences between the first and second determination was 7 +/- 7% for the LAD, 6 +/- 3% for LCx and 4 +/- 2% for the RCA (mean +/- SD). Correlation coefficients between both measurements were 0.97, 0.95 and 0.95 for the respective arteries. Therefore, it is concluded that, using this approach, Tmn at maximal hyperemia can be determined reproducibly in man and used for maximal myocardial flow assessment.

摘要

在通过心电图触发的数字射线摄影评估心肌灌注时,时间参数是根据时间密度曲线(TDC)计算得出并与血流相关。最近我们开发了一种方法,该方法使用平均通过时间(Tmn)作为时间参数,并且符合指示剂稀释理论的原始原理。在这种方法中,血管容积的变异性被排除,并且在最大充血时确定的Tmn-1在动物验证研究中与最大血流显示出极好的相关性。然而,为了可靠地外推,计算Tmn需要知道TDC下降支的很大一部分,尤其是在人体中,曲线的这一部分容易受到图像质量变化的影响。因此,我们测试了20名患者30条动脉中Tmn的可重复性。Tmn来自TDC,这些TDC是在相同情况下间隔10分钟进行的配对研究中获得的。除一名患者外,所有患者均可获得满意的图像。在配对研究中以相同的方式进行图像处理。结果证明,所有三支冠状动脉的可重复性都非常好。左前降支(LAD)第一次和第二次测定的相对差异绝对值为7±7%,左旋支(LCx)为6±3%,右冠状动脉(RCA)为4±2%(平均值±标准差)。各动脉两次测量之间的相关系数分别为0.97、0.95和0.95。因此,可以得出结论,使用这种方法,可以在人体中可重复地确定最大充血时的Tmn,并用于评估最大心肌血流。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验