Department of Ophthalmology, Maastricht University Medical Center, Maastricht, The Netherlands.
J Cataract Refract Surg. 2010 Nov;36(11):1897-904. doi: 10.1016/j.jcrs.2010.05.030.
To evaluate visual outcomes and patient satisfaction after implantation of an aspheric apodized diffractive intraocular lens (IOL) or a spherical apodized diffractive IOL in cataract surgery.
Maastricht University Medical Center, The Netherlands.
Nonrandomized clinical trial.
This prospective nonrandomized study with a 6-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL and a spherical AcrySof ReSTOR SN60D3 IOL. Main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuities, straylight levels, incidence of glare and halos, and contrast sensitivity levels.
The mean UDVA was 0.14 ± 0.15 logMAR in the aspheric group (47 eyes) and 0.14 logMAR ± 0.17 (SD) in the spherical group (45 eyes) and the mean CDVA, -0.01 ± 0.06 logMAR and 0.02 ± 0.10 logMAR, respectively. The mean UNVA was Jaeger (J) 1 in 83.0% of patients in the aspheric group and 55.5% of patients in the spherical IOL group (P = .003). The DCNVA was J1 in 95.7% and 71.1%, respectively (P = .001). There were no significant differences between the 2 groups in contrast sensitivity levels, intraocular straylight levels, incidence of night-vision symptoms, or subjective rating of vision.
Patients with the aspheric multifocal IOL had significantly better near vision than patients with the multifocal spherical IOL. The UDVA, CDVA, intraocular straylight, night-vision symptoms, and contrast sensitivity were similar between the 2 groups.
评估白内障手术后植入非球面消色差衍射型人工晶状体(IOL)或球面消色差衍射型 IOL 的视力结果和患者满意度。
荷兰马斯特里赫特大学医学中心。
非随机临床试验。
这项前瞻性非随机研究随访 6 个月,比较了白内障手术后植入非球面 AcrySof ReSTOR SN6AD3 IOL 和球面 AcrySof ReSTOR SN60D3 IOL 的结果。主要观察指标为未矫正(UDVA)和矫正(CDVA)远视力、未矫正(UNVA)和远距矫正(DCNVA)近视力、像散光水平、眩光和晕影发生率以及对比敏感度水平。
在非球面组(47 只眼)中,平均 UDVA 为 0.14 ± 0.15 logMAR,球面组(45 只眼)为 0.14 logMAR ± 0.17(SD),平均 CDVA 分别为-0.01 ± 0.06 logMAR 和 0.02 ± 0.10 logMAR。非球面组 83.0%的患者 UNVA 为 J1,球面 IOL 组为 55.5%(P =.003)。DCNVA 分别为 J1 和 71.1%(P =.001)。两组间对比敏感度水平、眼内像散光水平、夜间视力症状发生率或视觉主观评分无显著差异。
与多焦点球面 IOL 相比,植入非球面多焦点 IOL 的患者近视力明显更好。两组患者的 UDVA、CDVA、眼内像散光、夜间视力症状和对比敏感度相似。