Department of Analytical Chemistry, Faculty of Pharmacy, University of Mansoura, Mansoura 35516, Egypt.
J Fluoresc. 2011 Mar;21(2):715-22. doi: 10.1007/s10895-010-0761-7. Epub 2010 Nov 3.
Sensitive and simple spectrophotometric (Method I) and spectrofluorimetric (Method II) methods were developed and validated for the determination of oxybutynin HCl (OXB) in its dosage forms. The method was based on the reaction of OXB with malonic acid anhydride in acetic acid anhydride to form a highly yellow colored product that was measured at 375 nm spectrophotometrically. The same reaction product exihibits strong fluorescence that was measured at 440 nm after excitation at 390 nm. The factors affecting formation and stability of the reaction product were carefully studied and optimized, and the reaction mechanism was postulated. The absorbance-concentration plot is rectilinear over the range 4-40 μg/mL with LOD of 1.12 μg/mL and LOQ of 3.39 μg/mL. The fluorescence-concentration plot is rectilinear over the range 0.5-6 μg/mL with LOD of 0.11 μg/mL and LOQ of 0.33 μg/mL. The method was applied to the analysis of commercial tablets Detronin® and Uripan®. Statistical comparison of the results with those of the reference method revealed good agreement and proved that there were no significant difference in the accuracy and precision between the two methods respectively. The study was extended to content uniformity testing.
建立并验证了一种灵敏、简便的分光光度法(方法 I)和荧光分光光度法(方法 II),用于测定盐酸奥昔布宁(OXB)的含量。该方法基于 OXB 在乙酸酐中的丙二酸酐反应生成一种高度黄色的产物,可在 375nm 处进行分光光度法测定。同样的反应产物在 390nm 激发后,在 440nm 处显示出强荧光。仔细研究并优化了影响反应产物形成和稳定性的因素,并提出了反应机理。吸光度-浓度曲线在 4-40μg/mL 范围内呈线性,LOD 为 1.12μg/mL,LOQ 为 3.39μg/mL。荧光-浓度曲线在 0.5-6μg/mL 范围内呈线性,LOD 为 0.11μg/mL,LOQ 为 0.33μg/mL。该方法应用于商业片剂 Detronin®和 Uripan®的分析。与参考方法的结果进行统计学比较表明,两种方法的准确性和精密度无显著差异。研究还扩展到含量均匀度测试。