Suppr超能文献

血浆置换期间静脉输注0.9%氯化钠溶液对血浆中IgG含量的影响。

Influence of NaCl 0.9% Infusion during Plasmapheresis on IgG Content in Plasma.

作者信息

Evers Josef, Betz Jochen, Blankenburg Thomas, Engelen Tanja, Galle Gabriele, Hansen Michael, Laitinen Teija, Taborski Uwe

机构信息

Deutsche Gesellschaft für Humanplasma (DGH), Plasmazentrum Aachen, Germany.

出版信息

Transfus Med Hemother. 2010;37(4):191-194. doi: 10.1159/000317092. Epub 2010 Jul 14.

Abstract

BACKGROUND

The aim of this study was to evaluate the influence of an infusion of NaCl 0.9% 500 ml during preparatory plasmapheresis or apheresis on the immunoglobulin G (IgG) content in separated plasma. METHODS: 32 donors of plasma were studied in a crossover design after informed consent on one day without NaCl 0.9% 500 ml during apheresis and on another day with infusion of NaCl 0.9% 500 ml during apheresis. Infusion of NaCl 0.9% 500 ml was given step by step in divided doses after each cycle through the harness set of the Haemonetics® plasma collecting system 2 (PCS2). Concentrations of IgG in serum and in plasma were measured by an immunoturbidimetric assay. Percentages of IgG concentrations in plasma were calculated by dividing the IgG concentration in plasma by the mean serum IgG concentrations (x 100). RESULTS: Without infusion of NaCl 0.9% 500 ml, the mean percentage of IgG in separated plasma was 85.5 ± 2.3% while it was 80.5 ± 3.4% when NaCl 0.9% 500 ml was given. The difference between the two samples was statistically highly significant (p < 0.001). CONCLUSIONS: We conclude that the gradual infusion of NaCl 0.9% 500 ml during apheresis causes a statistically highly significant difference of IgG content in separated plasma.

摘要

背景

本研究的目的是评估在制备性血浆置换或血液成分单采过程中输注500毫升0.9%氯化钠溶液对分离血浆中免疫球蛋白G(IgG)含量的影响。方法:32名血浆捐献者在获得知情同意后,采用交叉设计进行研究,一天在血液成分单采过程中不输注500毫升0.9%氯化钠溶液,另一天在血液成分单采过程中输注500毫升0.9%氯化钠溶液。通过Haemonetics®血浆采集系统2(PCS2)的管路装置,在每个循环后分剂量逐步输注500毫升0.9%氯化钠溶液。采用免疫比浊法测定血清和血浆中IgG的浓度。血浆中IgG浓度的百分比通过将血浆中IgG浓度除以血清IgG平均浓度(×100)来计算。结果:不输注500毫升0.9%氯化钠溶液时,分离血浆中IgG的平均百分比为85.5±2.3%,而输注500毫升0.9%氯化钠溶液时为80.5±3.4%。两个样本之间的差异具有高度统计学意义(p<0.001)。结论:我们得出结论,在血液成分单采过程中逐步输注500毫升0.9%氯化钠溶液会导致分离血浆中IgG含量产生高度统计学意义的差异。

相似文献

7
Blood component collection by apheresis.通过单采术采集血液成分。
J Clin Apher. 2006 Jul;21(2):142-51. doi: 10.1002/jca.20043.
8
Protein levels and plasmapheresis intensity.蛋白质水平与血浆置换强度。
Transfus Med. 1993 Mar;3(1):59-65. doi: 10.1111/j.1365-3148.1993.tb00105.x.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验