对10匹温血马在静息、运动期间和运动后通过遥测心电图记录检测心律失常的观察者一致性。

Observer agreement for detection of cardiac arrhythmias on telemetric ECG recordings obtained at rest, during and after exercise in 10 Warmblood horses.

作者信息

Trachsel D S, Bitschnau C, Waldern N, Weishaupt M A, Schwarzwald C C

机构信息

Equine Department, Vetsuisse Faculty, University of Zurich, Switzerland.

出版信息

Equine Vet J Suppl. 2010 Nov(38):208-15. doi: 10.1111/j.2042-3306.2010.00172.x.

Abstract

REASONS FOR PERFORMING STUDY

Frequent supraventricular or ventricular arrhythmias during and after exercise are considered pathological in horses. Prevalence of arrhythmias seen in apparently healthy horses is still a matter of debate and may depend on breed, athletic condition and exercise intensity.

OBJECTIVES

To determine intra- and interobserver agreement for detection of arrhythmias at rest, during and after exercise using a telemetric electrocardiography device.

MATERIALS AND METHODS

The electrocardiogram (ECG) recordings of 10 healthy Warmblood horses (5 of which had an intracardiac catheter in place) undergoing a standardised treadmill exercise test were analysed at rest (R), during warm-up (W), during exercise (E), as well as during 0-5 min (PE(0-5)) and 6-45 min (PE(6-45)) recovery after exercise. The number and time of occurrence of physiological and pathological 'rhythm events' were recorded. Events were classified according to origin and mode of conduction. The agreement of 3 independent, blinded observers with different experience in ECG reading was estimated considering time of occurrence and classification of events.

RESULTS

For correct timing and classification, intraobserver agreement for observer 1 was 97% (R), 100% (W), 20% (E), 82% (PE(0-5)) and 100% (PE(6-45)). Interobserver agreement between observer 1 vs. observer 2 and between observer 1 vs. 3, respectively, was 96 and 92.6% (R), 83 and 31% (W), 0 and 13% (E), 23 and 18% (PE(0-5)), and 67 and 55% (PE(6-45)). When including the events with correct timing but disagreement for classification, the intraobserver agreement increased to 94% during PE(0-5) and the interobserver agreement reached 83 and 50% (W), 20 and 50% (E), 41 and 47% (PE(0-5)), and 83.5 and 65% (PE(6-45)). The interobserver agreement increased with observer experience.

CONCLUSIONS

Intra- and interobserver agreement for recognition and classification of events was good at R, but poor during E and poor-moderate during recovery periods. These results highlight the limitations of stress ECG in horses and the need for high-quality recordings and adequate observer training.

摘要

开展本研究的原因

马在运动期间及运动后频繁出现室上性或室性心律失常被认为是病理性的。在看似健康的马匹中观察到的心律失常患病率仍存在争议,可能取决于品种、运动状态和运动强度。

目的

使用遥测心电图设备确定观察者在静息、运动期间及运动后检测心律失常的观察者内和观察者间一致性。

材料与方法

对10匹健康温血马(其中5匹已植入心内导管)进行标准化跑步机运动试验时的心电图(ECG)记录进行分析,记录静息(R)、热身期间(W)、运动期间(E)以及运动后0 - 5分钟(PE(0 - 5))和6 - 45分钟(PE(6 - 45))恢复期间的情况。记录生理和病理性“节律事件”的数量和发生时间。根据起源和传导方式对事件进行分类。考虑事件的发生时间和分类,评估3名在心电图解读方面经验不同的独立、盲法观察者之间的一致性。

结果

对于正确的时间和分类,观察者1的观察者内一致性在静息时为97%(R),热身时为100%(W),运动时为20%(E),运动后0 - 5分钟为82%(PE(0 - 5)),运动后6 - 45分钟为100%(PE(6 - 45))。观察者1与观察者2之间以及观察者1与观察者3之间的观察者间一致性分别为:静息时96%和92.6%(R),热身时83%和31%(W),运动时0%和13%(E),运动后0 - 5分钟23%和18%(PE(0 - 5)),运动后6 - 45分钟67%和55%(PE(6 - 45))。当纳入时间正确但分类存在分歧的事件时,运动后0 - 5分钟期间观察者内一致性增至94%,观察者间一致性在热身时达到83%和50%(W),运动时达到20%和50%(E),运动后0 - 5分钟达到41%和47%(PE(0 - 5)),运动后6 - 45分钟达到83.5%和65%(PE(6 - 45))。观察者间一致性随观察者经验增加而提高。

结论

观察者内和观察者间对事件的识别和分类一致性在静息时良好,但在运动期间较差,恢复期间为中等到较差。这些结果凸显了马匹应激心电图的局限性以及高质量记录和充分观察者培训的必要性。