Thermal response of tissues to millimeter waves: implications for setting exposure guidelines.

机构信息

Department of Bioengineering, University of Pennsylvania, 210 S. 33rd Street, Philadelphia, PA 19104, USA.

出版信息

Health Phys. 2010 Dec;99(6):806-10. doi: 10.1097/HP.0b013e3181db29e6.

Abstract

This Note discusses the implications of a simple model for the thermal response of tissue subject to irradiation with millimeter waves (30-300 GHz) for setting limits for safe exposure to this energy. The estimated thresholds for thermal pain and thermal injury from long-term (minutes) and short-term (seconds) exposures are compared with two major exposure guidelines, IEEE C95.1-2005 and ICNIRP limits. An Appendix describes the rationale for setting the "averaging times" in IEEE C95.1-2005.

摘要

本说明讨论了一个简单模型对组织在毫米波(30-300GHz)照射下的热响应的影响,以便为这种能量的安全暴露设定限制。将长期(分钟)和短期(秒)暴露引起的热痛和热损伤的估计阈值与 IEEE C95.1-2005 和 ICNIRP 限值这两个主要的暴露指南进行了比较。附录描述了在 IEEE C95.1-2005 中设置“平均时间”的基本原理。