使用Orbitrap™ 质谱仪的生物分析液相色谱-质谱联用技术进展

Advances in bioanalytical LC-MS using the Orbitrap™ mass analyzer.

作者信息

Scigelova Michaela, Makarov Alexander

机构信息

Thermo Fisher Scientific, Hanna-Kunath-Str. 11, 28199 Bremen, Germany.

出版信息

Bioanalysis. 2009 Jul;1(4):741-54. doi: 10.4155/bio.09.65.

Abstract

The continuing desire to analyze complex biological samples with the minimum number of steps places high demands on increasing speed, dynamic signal range, quantitative capability and the facility with which the mass spectrometers can interface with chromatographic separation methods. Reliable identification of metabolites in complex mixtures requires robust mass spectrometers with high resolving power, mass accuracy, sensitivity and dynamic range, while tandem MS is an invaluable tool for further structural characterization. This review begins with a discussion of the key properties of the Orbitrap™ mass analyzer: mass accuracy, resolution, fidelity of isotope pattern abundancies and dynamic range. The main objective is to provide an overview of Orbitrap applications in the field of bioanalysis. Specific areas of drug metabolism, doping control and food contaminants are discussed in detail illustrating the performance and versatility of the Orbitrap mass analyzer.

摘要

人们一直希望通过最少的步骤来分析复杂的生物样品,这对提高速度、动态信号范围、定量能力以及质谱仪与色谱分离方法联用的便利性提出了很高的要求。可靠鉴定复杂混合物中的代谢物需要具备高分辨能力、质量精度、灵敏度和动态范围的强大质谱仪,而串联质谱是进行进一步结构表征的宝贵工具。本综述首先讨论了Orbitrap™ 质量分析器的关键特性:质量精度、分辨率、同位素模式丰度的保真度和动态范围。主要目的是概述Orbitrap在生物分析领域的应用。详细讨论了药物代谢、兴奋剂检测和食品污染物等特定领域,以说明Orbitrap质量分析器的性能和通用性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验