孕妇身体活动监测器的准确性。

Accuracy of physical activity monitors in pregnant women.

机构信息

The University of Tennessee, Knoxville, TN, USA.

出版信息

Med Sci Sports Exerc. 2011 Jun;43(6):1100-5. doi: 10.1249/MSS.0b013e3182058883.

Abstract

PURPOSE

To determine the step count accuracy of three pedometers and one accelerometer in pregnant women during treadmill walking.

METHODS

Participants were 30 women in the second or third trimester (20-34 wk) who were screened for pregnancy-related risk factors. Each participant was fitted with a belt containing three physical activity monitors: Yamax Digiwalker SW-200 (DW), New Lifestyles NL 2000 (NL), and GT3X ActiGraph accelerometer (ACT). The Omron HJ-720ITC (HJ) was placed in the pants' front pocket. Participants walked at 54, 67, 80, and 94 m · min for 2 min each. Actual steps were determined by an investigator using a hand-tally counter. The mean percent of steps recorded was calculated for each device at each speed and compared. Pearson correlations were used to determine the effect of body mass index and tilt angle on pedometer accuracy.

RESULTS

There was a significant interaction between speed and device (F9,20 = 7.574, P < 0.001). Across all speeds, the NL and HJ had the lowest error. The ACT and DW underestimated the actual steps taken, particularly at the slower walking speeds. At 54 m · min, the ACT averaged 77.5% of steps and the DW averaged 56.9% of steps. Significant differences in the mean percent of steps recorded were found between devices at all speeds. Body mass index was only significantly correlated with percent of steps recorded by the NL, and there were no significant correlations between steps recorded and tilt angle.

CONCLUSIONS

In pregnant women, the ACT and DW had more error than the NL and HJ. On the basis of these results, the NL and HJ should be considered for use in further research studies and physical activity programs that focus on walking during pregnancy.

摘要

目的

确定三种计步器和一种加速度计在孕妇跑步机行走时的计步准确性。

方法

参与者为 30 名处于第二或第三孕期(20-34 周)的女性,这些女性接受了与妊娠相关的风险因素筛查。每位参与者都佩戴了一个包含三个身体活动监测器的腰带:Yamax Digiwalker SW-200(DW)、New Lifestyles NL 2000(NL)和 GT3X ActiGraph 加速度计(ACT)。Omron HJ-720ITC(HJ)放在裤子前口袋里。参与者以 54、67、80 和 94 m·min 的速度各行走 2 分钟。实际步数由一名研究员使用手动计数器确定。计算了每个设备在每个速度下记录的平均步数百分比,并进行了比较。Pearson 相关性用于确定体重指数和倾斜角度对计步器准确性的影响。

结果

速度和设备之间存在显著的交互作用(F9,20 = 7.574,P < 0.001)。在所有速度下,NL 和 HJ 的误差最小。ACT 和 DW 低估了实际的步数,尤其是在较慢的步行速度下。在 54 m·min 时,ACT 的平均步数为 77.5%,DW 的平均步数为 56.9%。在所有速度下,记录的平均步数百分比在设备之间存在显著差异。体重指数仅与 NL 记录的步数百分比显著相关,而记录的步数与倾斜角度之间没有显著相关性。

结论

在孕妇中,ACT 和 DW 的误差比 NL 和 HJ 大。基于这些结果,NL 和 HJ 应考虑用于进一步的研究和以妊娠期间行走为重点的体育活动计划。