Suppr超能文献

年龄与屈光度和中央角膜厚度的关系。

Relationship of age and refraction to central corneal thickness.

机构信息

Department of Ophthalmology, UMDNJ-New Jersey Medical School, Newark, NJ, USA.

出版信息

Cornea. 2011 May;30(5):553-5. doi: 10.1097/ICO.0b013e3181fb880c.

Abstract

PURPOSE

To obtain descriptive statistics of central corneal thickness (CCT) in a large population of normal eyes undergoing refractive surgery and study the relationship of 2 variables, age and refraction, with CCT.

SETTING

Cornea and Laser Eye Institute, Hersh Vision Group, Teaneck, NJ.

METHODS

The CCT of 5158 patients was measured using an ultrasound pachymeter. Age and preoperative spherical equivalent were recorded for all patients. The entire population and subgroups stratified to age and spherical equivalent were analyzed.

RESULTS

Mean CCT was 544 μm with an SD of 34 μm and a range of 415-695 μm. CCT did not correlate with either age (r = 0.00645) or refraction (r = 0.00072).

CONCLUSIONS

This study defines the CCT in a large population of patients undergoing refractive surgery. In this population, age and refraction did not affect CCT.

摘要

目的

获取接受屈光手术的大量正常眼中央角膜厚度(CCT)的描述性统计数据,并研究年龄和屈光度这两个变量与 CCT 的关系。

地点

新泽西州特伦克的角膜和激光眼科研究所,赫什视力集团。

方法

使用超声角膜测厚仪测量 5158 例患者的 CCT。记录所有患者的年龄和术前等效球镜。对整个人群以及按年龄和等效球镜分层的亚组进行分析。

结果

平均 CCT 为 544μm,标准差为 34μm,范围为 415-695μm。CCT 与年龄(r = 0.00645)或屈光度(r = 0.00072)均无相关性。

结论

本研究定义了接受屈光手术的大量患者的 CCT。在该人群中,年龄和屈光度不影响 CCT。