Department of Fixed Prosthodontics, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt.
J Am Dent Assoc. 2010 Dec;141(12):1459-66. doi: 10.14219/jada.archive.2010.0108.
The authors investigated the postcementation sensitivity associated with self-adhesive resin cements used with fixed partial dentures (FPDs).
The authors recruited 20 patients who needed posterior porcelain-fused-to-metal FPDs and divided them randomly into three groups. They prepared 50 abutments, then cemented FPDs with one of two self-adhesive resin cements (Breeze Self-Adhesive Resin Cement, Pentron Clinical Technologies, Wallingford, Conn., and RelyX Unicem Self-Adhesive Universal Resin Cement, 3M ESPE, Seefeld, Germany) or an etch-and-rinse resin cement (RelyX ARC Adhesive Resin Cement, 3M ESPE, St. Paul, Minn.). The authors measured participants' tooth sensitivity to cold water, air blast and biting at 24 hours and at two, six and 12 weeks after FPD cementation by using a continuous visual analog scale (VAS). Data were analyzed statistically by means of the Mann-Whitney test.
For cold tests, the highest VAS scores occurred 24 hours after cementation. The mean VAS scores associated with RelyX ARC were significantly higher than those associated with Breeze and RelyX Unicem (P < .001) at all test intervals. The mean cold-test VAS scores associated with Breeze and RelyX Unicem were not significantly different (P > .05). With all cements, sensitivity to cold decreased significantly after two to six weeks; however, with RelyX ARC, VAS scores stayed above the 30 percent level even after 12 weeks. The biting sensitivity associated with RelyX ARC was significantly higher than that associated with Breeze and RelyX Unicem (P < .001), and it remained above the 20 percent level even after 12 weeks. Those with Breeze-cemented FPDs had no sensitivity to biting, whereas those with RelyX Unicem-cemented FPDs had a mean biting sensitivity value of less than 5 percent at two weeks only.
and
Breeze and RelyX Unicem were associated with significantly lower postoperative tooth sensitivity values than was RelyX ARC. With Breeze and RelyX Unicem, postoperative tooth sensitivity disappeared after two to six weeks; however, with RelyX ARC it remained even after 12 weeks. Clinicians may use self-adhesive resin cements, and benefit from their bonding potential, without fear of patients' developing tooth sensitivity.
作者研究了与固定局部义齿(FPD)一起使用的自粘树脂水门汀的粘固后敏感性。
作者招募了 20 名需要后牙烤瓷熔附金属 FPD 的患者,并将其随机分为三组。他们预备了 50 个基牙,然后用两种自粘树脂水门汀(Breeze 自粘树脂水门汀,Pentron Clinical Technologies,Wallingford,Conn. 和 RelyX Unicem 自粘通用树脂水门汀,3M ESPE,Seefeld,德国)或一种酸蚀-冲洗树脂水门汀(RelyX ARC 粘结树脂水门汀,3M ESPE,St. Paul,Minn.)粘结 FPD。作者通过连续视觉模拟量表(VAS)在 24 小时以及粘固 FPD 后 2、6 和 12 周时测量患者对冷水、空气喷射和咬合的牙齿敏感性。通过 Mann-Whitney 检验对数据进行统计学分析。
对于冷测试,粘固后 24 小时 VAS 评分最高。在所有测试间隔中,与 RelyX ARC 相关的平均 VAS 评分明显高于与 Breeze 和 RelyX Unicem 相关的评分(P <.001)。Breeze 和 RelyX Unicem 相关的冷测试 VAS 评分无显著差异(P >.05)。所有水门汀的冷敏感性在 2 至 6 周后显著降低;然而,RelyX ARC 的 VAS 评分甚至在 12 周后仍保持在 30%以上。与 RelyX ARC 相关的咬合敏感性明显高于与 Breeze 和 RelyX Unicem 相关的敏感性(P <.001),即使在 12 周后,其仍保持在 20%以上。用 Breeze 粘结的 FPD 无咬合敏感性,而用 RelyX Unicem 粘结的 FPD 在 2 周时仅具有低于 5%的平均咬合敏感性值。
Breeze 和 RelyX Unicem 与 RelyX ARC 相比,术后牙齿敏感性值显著降低。用 Breeze 和 RelyX Unicem,术后牙齿敏感性在 2 至 6 周后消失;然而,用 RelyX ARC,即使在 12 周后仍存在。临床医生可以使用自粘树脂水门汀,并受益于其粘结潜力,而不必担心患者出现牙齿敏感性。