Anadolu University, Faculty of Science, Department of Chemistry, 26470 Eskisehir, Turkey.
Anal Chim Acta. 2011 Jan 24;685(1):9-14. doi: 10.1016/j.aca.2010.11.004. Epub 2010 Nov 10.
A novel approach was proposed for the simple and rapid electrochemical determination of paracetamol (PC) in the presence of uric acid in body fluids. The voltammetric determination of PC is based on the electrochemical reduction of N-acetyl-p-benzoquinoneimine formed simultaneously on the electrochemically treated pencil graphite (ETPG) electrode during the measurement. ETPG electrodes were prepared by the potential cycling between -0.3V and +2.0V in 0.1M H(3)PO(4) solution. The electrochemical performance of the ETPG electrode was evaluated by adsorptive transfer stripping differential pulse voltammetry (ATSDPV). The resulting sensor showed good performance for the determination of PC in human blood serum samples with a linear range of 0.05-2.5 μM and a highly reproducible response (RSD of 3.1%). The calculated detection limit was 2.5 nM (S/N=3). The proposed method does not require any sample pretreatment, prevents the interference of uric acid and allows the determination of PC directly in blood serum samples.
提出了一种新方法,用于在体液中存在尿酸的情况下简单快速地电化学测定扑热息痛(PC)。PC 的伏安法测定基于在电化学处理的铅笔石墨(ETPG)电极上同时形成的 N-乙酰对苯醌亚胺的电化学还原,该电极是在 0.1M H(3)PO(4)溶液中在-0.3V 和+2.0V 之间进行电位循环制备的。通过吸附传递 stripping 差分脉冲伏安法(ATSDPV)评估 ETPG 电极的电化学性能。所得传感器对人血清样品中 PC 的测定表现出良好的性能,线性范围为 0.05-2.5 μM,重现性好(RSD 为 3.1%)。计算的检测限为 2.5 nM(S/N=3)。该方法不需要任何样品预处理,可防止尿酸的干扰,并允许直接在血清样品中测定 PC。