Discipline of Exercise and Sport Science, Faculty of Health Sciences, University of Sydney, 75 East Street, Lidcombe, NSW, 2141, Australia.
Eur J Appl Physiol. 2011 Aug;111(8):1561-9. doi: 10.1007/s00421-010-1781-3. Epub 2010 Dec 28.
Muscle weakness following constant load exercise under heat stress has been associated with hyperthermia-induced central fatigue. However, evidence of central fatigue influencing intense self-paced exercise in the heat is lacking. The purpose of this investigation was to evaluate force production capacity and central nervous system drive in skeletal muscle pre- and post-cycle ergometer exercise in hot and cool conditions. Nine trained male cyclists performed a 20-s maximal voluntary isometric contraction (MVC) prior to (control) and following a 40-km time trial in hot (35°C) and cool (20°C) conditions. MVC force production and voluntary activation of the knee extensors was evaluated via percutaneous tetanic stimulation. In the cool condition, rectal temperature increased to 39.0°C and reached 39.8°C in the heat (P < 0.01). Following exercise in the hot and cool conditions, peak force declined by ~90 and ~99 N, respectively, compared with control (P < 0.01). Mean force decreased by 15% (hot) and 14% (cool) (P < 0.01 vs. control). Voluntary activation during the post-exercise MVC declined to 93.7% (hot) and 93.9% (cool) (P < 0.05 vs. control). The post-exercise decline in voluntary activation represented ~20% of the decrease in mean force production in both conditions. Therefore, the additional increase in rectal temperature did not exacerbate the loss of force production following self-paced exercise in the heat. The impairment in force production indicates that the fatigue exhibited by the quadriceps is mainly of peripheral origin and a consequence of the prolonged contractile activity associated with exercise.
在热应激下进行持续负荷运动后出现的肌肉无力与热诱导的中枢疲劳有关。然而,中枢疲劳对热环境下高强度自我调节运动的影响的证据尚缺乏。本研究旨在评估热和凉爽条件下,在踏车测力计运动前后,骨骼肌的力量产生能力和中枢神经系统驱动。9 名训练有素的男性自行车运动员在热(35°C)和凉爽(20°C)条件下进行 40 公里计时赛后,进行了 20 秒最大自主等长收缩(MVC)前(对照)和后(MVC)的 20 秒最大自主等长收缩(MVC)。通过经皮强直刺激评估膝关节伸肌的最大力量产生和自愿激活。在凉爽条件下,直肠温度升高至 39.0°C,在热环境下达到 39.8°C(P < 0.01)。与对照相比,在热和凉爽条件下运动后,峰值力分别下降了约 90 和 99 N(P < 0.01)。平均力下降了 15%(热)和 14%(冷)(P < 0.01 与对照)。运动后 MVC 期间的自愿激活下降至 93.7%(热)和 93.9%(冷)(P < 0.05 与对照)。在两种情况下,运动后自愿激活的下降代表了平均力量产生下降的约 20%。因此,直肠温度的额外升高并没有加剧热环境下自我调节运动后力量产生的丧失。力量产生的受损表明,股四头肌表现出的疲劳主要是外周起源的,是与运动相关的长时间收缩活动的结果。