Department of Chemistry, University of Washington, Seattle, Washington 98195-1700, USA.
Anal Chem. 2011 Feb 1;83(3):1152-6. doi: 10.1021/ac102777s. Epub 2010 Dec 30.
We have developed a tandem mass spectrometry based assay of iduronate-2-sulfatase (IdS) activity for the neonatal detection of mucopolysaccharidosis II (MPS-II, Hunter Syndrome). The assay uses a newly designed synthetic substrate (IdS-S) consisting of α-L-iduronate-2-sulfate, which is glycosidically conjugated to a coumarin and a linker containing a tert-butyloxycarbamido group. A short synthesis of the substrate has been developed that has the potential of being scaled to multigram quantities. Sulfate hydrolysis of IdS-S by IdS found within a 3 mm dried blood spot specifically produces a nonsulfated product (IdS-P) which is detected by electrospray tandem mass spectrometry and quantified using a deuterium-labeled internal standard, both carried out in positive ion mode. Analysis of DBS from 75 random human newborns showed IdS activities in the range of 4.8-16.2 (mean 9.1) μmol/(h L of blood), which were clearly distinguished from the activities measured for 14 MPS-II patients at 0.17-0.52 (mean 0.29) μmol/(h L of blood). The assay shows low blank activity, 0.15 ± 0.03 μmol/(h L of blood). The within-assay coefficient of variation (CV) was 3.1% while the interassay CV was 15%.
我们开发了一种基于串联质谱的艾杜糖-2-硫酸酯酶(IdS)活性测定法,用于新生儿黏多糖贮积症 II 型(MPS-II,亨特综合征)的检测。该测定法使用一种新设计的合成底物(IdS-S),由 α-L-艾杜糖-2-硫酸盐组成,它与香豆素和含有叔丁氧羰基氨基的连接子糖基化共轭。该底物的短合成路线具有扩大到多克数量级的潜力。IdS-S 的硫酸盐水解由 3mm 干血斑内的 IdS 特异性产生非硫酸盐产物(IdS-P),通过电喷雾串联质谱检测,并使用氘标记的内标定量,均以正离子模式进行。对 75 名随机新生儿的 DBS 分析显示,IdS 活性范围为 4.8-16.2(平均值为 9.1)μmol/(hL 血液),与 14 名 MPS-II 患者的 0.17-0.52(平均值为 0.29)μmol/(hL 血液)测量值明显区分开来。该测定法显示出低空白活性,为 0.15±0.03μmol/(hL 血液)。批内变异系数(CV)为 3.1%,批间 CV 为 15%。