通过体内荧光反射成像技术减少体厚对显示小鼠深层腹部淋巴结的定量影响。

Quantitative effect of reducing body thickness on visualizing murine deep abdominal lymph nodes by in vivo fluorescence reflectance imaging.

机构信息

Department of Diagnostic Radiology, Kitasato University School of Medicine, 1-15-1 Kitasato, Sagamihara, Kanagawa 252-0374, Japan.

出版信息

J Fluoresc. 2011 Jul;21(4):1325-9. doi: 10.1007/s10895-010-0828-5. Epub 2011 Jan 12.

Abstract

Scattering and absorption in the tissues are major problems for in vivo imaging based on a fluorescence reflectance imaging technique. We evaluated the quantitative relationship between body thickness and fluorescent signals from a deep abdominal source in intact mice. Mice were injected with quantum dots (peak emission, 800 nm) into the right rear footpad, and fluorescent signals from the iliac lymph node located deeply in the abdomen were assessed by fluorescence reflectance imaging. Stepwise compression of the mouse abdomen to reduce the body thickness was attained using a homemade simple device. The iliac node signals were weak and diffuse without compression but became stronger and more localized with decreasing body thickness. Using excitation light of approximately 710 nm wavelength, the lymph node/background contrast increased about 16 times with a 4 mm reduction in body thickness. Contrast enhancement was more evident using shorter wavelength excitation light. Overlying tissues profoundly affect signals from a deep source in fluorescence reflectance imaging. Our simple compression method may contribute to quantitatively assessing deep fluorescent sources.

摘要

组织中的散射和吸收是基于荧光反射成像技术的活体成像的主要问题。我们评估了来自完整小鼠深层腹部源的体厚与荧光信号之间的定量关系。将量子点(峰值发射,800nm)注入小鼠右后脚掌,并通过荧光反射成像评估位于腹部深处的髂淋巴结的荧光信号。使用自制的简单装置逐步压缩小鼠腹部以减小体厚。在没有压缩的情况下,髂淋巴结信号较弱且弥散,但随着体厚的减小,信号变得更强且更局限。使用约 710nm 波长的激发光,当体厚减少 4mm 时,淋巴结/背景对比度增加约 16 倍。使用较短波长的激发光,对比度增强更明显。覆盖组织会极大地影响荧光反射成像中深部源的信号。我们的简单压缩方法可能有助于定量评估深部荧光源。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验