Suppr超能文献

下肢功能筛查测试中的运动学——它们是否可靠且与慢跑相关?

Kinematics during lower extremity functional screening tests--are they reliable and related to jogging?

机构信息

Faculty of Health and Environmental Sciences, Health and Rehabilitation Research Centre and Sport Performance Research Institute New Zealand, AUT University, Private Bag 92006, Auckland, New Zealand.

出版信息

Phys Ther Sport. 2011 Feb;12(1):22-9. doi: 10.1016/j.ptsp.2010.10.006. Epub 2010 Dec 10.

Abstract

PURPOSE

To investigate the within-day and between-day reliability of 3D lower extremity kinematics during five lower extremity functional screening tests and to assess the association between these kinematics and those recorded during jogging.

METHODS

Peak three-dimensional lower extremity kinematics were quantified in 25 uninjured participants during five lower extremity functional tests and jogging. A nine camera motion analysis system (Qualysis Medical AB, Sweden) was used to capture three trials of all tests. All functional tests were repeated by 10 participants one to two days later. Visual 3D (C-Motion Inc, USA) and Labview were used to process all data. Intraclass correlation coefficients (ICC) and typical errors (TE) were used to assess within- and between-day reliability of all variables. Pearson correlation coefficients were used to evaluate the association between peak joint kinematics during the functional tests and jogging.

RESULTS

For the majority of kinematic variables the within-day reliability was excellent (ICC ≥ 0.92) and the between-day reliability was excellent to good (ICC ≥ 0.80). The correlation between kinematics of the functional tests and jogging was generally large to very large (r = 0.53 to 0.93).

CONCLUSIONS

These results suggest these lower extremity functional screening tests should prove a useful clinical tool when assessing dynamic lower extremity alignment.

摘要

目的

研究 5 种下肢功能筛查试验中 3D 下肢运动学的日内和日间可靠性,并评估这些运动学与慢跑时记录的运动学之间的相关性。

方法

25 名无损伤参与者在 5 种下肢功能测试和慢跑中定量分析了三维下肢运动学的峰值。使用九摄像机运动分析系统(瑞典 Qualysis Medical AB)捕获所有测试的三个试验。所有功能测试均由 10 名参与者在 1 至 2 天后重复进行。使用 Visual 3D(美国 C-Motion Inc.)和 Labview 处理所有数据。使用组内相关系数(ICC)和典型误差(TE)评估所有变量的日内和日间可靠性。使用皮尔逊相关系数评估功能测试和慢跑期间关节运动学峰值之间的相关性。

结果

对于大多数运动学变量,日内可靠性非常好(ICC≥0.92),日间可靠性非常好到良好(ICC≥0.80)。功能测试和慢跑之间的运动学相关性通常较大到非常大(r=0.53 至 0.93)。

结论

这些结果表明,当评估动态下肢对线时,这些下肢功能筛查试验应该是一种有用的临床工具。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验