Suppr超能文献

使用荧光法测量多个或单个咬合性病变对诊断准确性估计的影响。

Impact of measuring multiple or single occlusal lesions on estimates of diagnostic accuracy using fluorescence methods.

机构信息

Department of Paediatric and Community Dentistry, Dental School, Philipps-University of Marburg, Georg-Voigt-Str. 3, 35033, Marburg, Germany.

出版信息

Lasers Med Sci. 2012 Mar;27(2):343-52. doi: 10.1007/s10103-011-0881-6. Epub 2011 Jan 29.

Abstract

Carious lesions can occur at different sites on the occlusal surfaces of teeth and may differ in appearance and severity. This study aimed to evaluate how scoring several lesions on occlusal surfaces, as opposed to only one representative lesion, affects estimates of reproducibility and accuracy of fluorescence-based devices. Thirty-six permanent teeth with 2-3 investigation sites (n = 82) were examined by two examiners using the laser fluorescence device DIAGNOdent pen (LF) and the fluorescence camera VistaProof (FC). Lesion depth was then assessed histologically in serial sections of the teeth. Intra-class-correlation coefficients (ICC) and areas under the ROC-curves were calculated for all investigation sites and for one randomly selected site per tooth. Comparing the reproducibility and the performance for the whole sample and the independent sites showed only a small effect or no effect. Measuring multiple sites on teeth with fluorescence devices only moderately influences performance compared to one site being investigated.

摘要

龋损可发生于牙齿的咬合面的不同部位,其表现和严重程度可能有所不同。本研究旨在评估在咬合面检查多个龋损部位,而非仅检查一个代表性部位,对基于荧光的设备的重复性和准确性估计值的影响。使用激光荧光设备 DIAGNOdent pen(LF)和荧光相机 VistaProof(FC),对 36 颗恒牙的 2-3 个检查部位(n=82)进行了两位检查者的检查。然后,通过对牙齿的连续切片进行组织学评估,确定病变深度。对所有检查部位和每颗牙随机选择的一个部位计算了组内相关系数(ICC)和 ROC 曲线下的面积。比较整个样本和独立部位的重复性和性能,仅显示出较小的影响或没有影响。与检查一个部位相比,使用荧光设备检查牙齿的多个部位仅会对性能产生适度影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验