Suppr超能文献

比较新型荧光相机与传统激光荧光设备在探测乳牙窝沟及平滑面龋损中的可靠性。

Comparing the reliability of a new fluorescence camera with conventional laser fluorescence devices in detecting caries lesions in occlusal and smooth surfaces of primary teeth.

机构信息

Department of Pediatric Dentistry, Faculdade de Odontologia da Universidade de São Paulo, São Paulo, Brazil.

出版信息

Lasers Med Sci. 2011 Mar;26(2):157-62. doi: 10.1007/s10103-010-0757-1. Epub 2010 Feb 16.

Abstract

The aims of this in vitro study were (1) to compare the reliability of a new fluorescence camera (FC; VistaProof) with that of two other laser fluorescence devices (DIAGNOdent and DIAGNOdent pen) in assessing smooth and occlusal caries lesions in primary teeth and (2) to determine the influence of the spacer, the protective cover and air drying on the FC readings. We selected 129 primary molars which were divided into two groups: smooth surfaces (n=68) and occlusal surfaces (n=61). Two trained examiners performed the evaluations using the FC and the other laser fluorescence devices separately. One examiner repeated all assessments after 1 week. Inter- and intraexaminer reproducibility was calculated from the absolute values derived from the devices using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Pearson correlation was performed among the values obtained with the different devices. For aim 2, only teeth from the occlusal surface group were used. Another examiner performed measurements with the FC, varying the size of the spacer, the use of the plastic protective cover and the drying time (0, 3 and 15 s). Wilcoxon's test was used to compare these measurements. High values of interexaminer ICC were observed with the FC in both experiments. However, the highest intraexaminer ICC for smooth surfaces was found for the DIAGNOdent (ICC 0.918). A positive correlation between all methods was observed in both studies. Only drying for 15 s significantly increased the FC readings. In conclusion, the FC showed high reliability for occlusal and smooth surfaces, similar to the other fluorescence methods tested. Additionally, prolonged air drying increased the FC measurements.

摘要

本体外研究的目的为

(1)比较新型荧光摄像仪(FC;VistaProof)与两种其他激光荧光设备(DIAGNOdent 和 DIAGNOdent pen)评估乳牙平滑面和窝沟龋损时的可靠性;(2)确定间隔物、保护套和空气干燥对 FC 读数的影响。我们选择了 129 颗乳磨牙,将其分为两组:平滑面(n=68)和窝沟面(n=61)。两名训练有素的检查者分别使用 FC 和其他激光荧光设备进行评估。一名检查者在 1 周后重复所有评估。通过设备获得的绝对值,使用组内相关系数(ICC)和 Bland-Altman 分析计算检查者内和检查者间的重现性。对不同设备获得的值进行 Pearson 相关性分析。对于目标 2,仅使用窝沟面组的牙齿。另一名检查者使用 FC 进行测量,改变间隔物的大小、使用塑料保护套和干燥时间(0、3 和 15 s)。使用 Wilcoxon 检验比较这些测量值。在两个实验中,FC 的检查者间 ICC 值均较高。然而,在平滑面中,DIAGNOdent 的检查者内 ICC 值最高(ICC 0.918)。两项研究中所有方法之间均呈正相关。仅干燥 15 s 会显著增加 FC 读数。总之,FC 对窝沟面和平滑面具有较高的可靠性,与所测试的其他荧光方法相似。此外,延长空气干燥时间会增加 FC 测量值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验