Suppr超能文献

肾动脉狭窄:非增强肾动脉 MRA 与对比增强 MRA 的对比评估。

Renal artery stenosis: comparative assessment by unenhanced renal artery MRA versus contrast-enhanced MRA.

机构信息

Department of MRI, St Mary's Hospital, Imperial College NHS Trust, London, UK.

出版信息

Eur Radiol. 2011 Jul;21(7):1470-6. doi: 10.1007/s00330-011-2086-6. Epub 2011 Feb 20.

Abstract

OBJECTIVES

To evaluate steady-state free precession (SSFP) non-contrast-enhanced MR angiography (Unenhanced-MRA) versus conventional contrast-enhanced MR angiography (CE-MRA) in the detection of renal artery stenosis (RAS).

METHODS

Retrospective analysis of 70 consecutive patients referred for suspected RAS, examined by SSFP Unenhanced-MRA and CE-MRA. Image quality, quality of visible renal arterial segments, presence and grade of RAS were evaluated. The Unenhanced-MRA were compared against reference standard CE-MRA results.

RESULTS

149 renal arteries were assessed with 21 haemodynamically significant stenoses (≥ 50% stenosis) demonstrated by CE-MRA. Combined sensitivity and specificity for RAS detection by Unenhanced-MRA was 72.8% and 97.8% respectively. There is substantial correlation for RAS detection between Unenhanced-MRA and CE-MRA with kappa values of between 0.64 and 0.74. There was excellent inter-observer correlation for RAS on Unenhanced-MRA (kappa values 0.82-1.0).

CONCLUSIONS

Our study has shown Unenhanced-MRA to be a viable alternative to CE-MRA, yielding images equal in quality without the requirement for gadolinium contrast agents. The sensitivity and specificity for the detection of haemodynamically significant stenoses are comparable to CE-MRA. Potentially, Unenhanced-MRA could be used as an initial investigation to avoid performing CE-MRA in patients with normal renal arteries, however we suggest that its real value will lie in being complementary to CE-MRA.

摘要

目的

评估稳态自由进动(SSFP)无对比增强磁共振血管成像(Unenhanced-MRA)与传统对比增强磁共振血管成像(CE-MRA)在检测肾动脉狭窄(RAS)中的应用。

方法

回顾性分析了 70 例连续疑似 RAS 患者,采用 SSFP Unenhanced-MRA 和 CE-MRA 进行检查。评估图像质量、可见肾动脉节段的质量、RAS 的存在和程度。将 Unenhanced-MRA 与参考标准 CE-MRA 结果进行比较。

结果

149 条肾动脉接受评估,CE-MRA 显示 21 条肾动脉狭窄(≥50%狭窄)有血流动力学意义。Unenhanced-MRA 检测 RAS 的敏感性和特异性分别为 72.8%和 97.8%。Unenhanced-MRA 和 CE-MRA 检测 RAS 的相关性较强,kappa 值在 0.64 至 0.74 之间。Unenhanced-MRA 上的 RAS 观察者间具有极好的相关性(kappa 值为 0.82-1.0)。

结论

本研究表明 Unenhanced-MRA 是 CE-MRA 的一种可行替代方法,可获得质量相等的图像,而无需使用钆对比剂。检测血流动力学意义重大狭窄的敏感性和特异性与 CE-MRA 相当。潜在地,Unenhanced-MRA 可以作为一种初始检查,避免在正常肾动脉患者中进行 CE-MRA,但是我们认为它的真正价值将在于与 CE-MRA 互补。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验