Zabelin N N, Kuzina L E, Kudriavtseva E N, Zabotina E E, Braginskiĭ D M, Malyshev N A, Kuzin S N, Samokhvalov E I, L'vov D K
Vopr Virusol. 2010 Nov-Dec;55(6):28-31.
The diagnostic capacities of 4 commercial test systems were comparatively estimated for the detection of HBsAg, by applying a panel of samples with the established amino acid sequence of the "a" determinant of HBsAg. The Roche Elecsys HBsAg test system demonstrated the highest sensitivity - the maximum HBsAg concentrations were found in 19 of 31 cases. Escape mutations in the major hydrophilic region (MHR) of HBsAG (P120S, M133T) were responsible for differences in the sensitivity of 4 test systems by 10- to 40-fold. There were also samples that showed differences in the diagnostic capacities of the test systems to detect HBsAg, but without amino acid replacements in the area of the "a" determinant, which seems to be associated with amino acid replacements in other regions of HBsAg.
通过应用一组具有已确定的 HBsAg “a” 决定簇氨基酸序列的样本,对 4 种商业检测系统检测 HBsAg 的诊断能力进行了比较评估。罗氏 Elecsys HBsAg 检测系统表现出最高的灵敏度——在 31 例中有 19 例检测到最高 HBsAg 浓度。HBsAG 主要亲水区域(MHR)中的逃逸突变(P120S、M133T)导致 4 种检测系统的灵敏度差异达 10 至 40 倍。也有一些样本显示检测系统在检测 HBsAg 的诊断能力上存在差异,但在 “a” 决定簇区域没有氨基酸替换,这似乎与 HBsAg 其他区域的氨基酸替换有关。