Suppr超能文献

RTVue - 100傅里叶域光学相干断层扫描仪在视神经病变筛查试验中的准确性。

Accuracy of the RTVue-100 Fourier-domain optical coherence tomograph in an optic neuropathy screening trial.

作者信息

Garas Anita, Kóthy Péter, Holló Gábor

机构信息

Department of Ophthalmology, Semmelweis University, Tömö u. 25-29, Budapest, Hungary.

出版信息

Int Ophthalmol. 2011 Jun;31(3):175-82. doi: 10.1007/s10792-011-9433-0. Epub 2011 Mar 20.

Abstract

The aim of this study was to evaluate the usefulness of the RTVue-100 Fourier-domain optical coherence tomograph (RTVue-100 OCT) in screening for glaucoma and non-arteritic anterior ischemic optic neuropathy (NA-AION). In a non-population-based pre-publicised trial, self-recruited Caucasian participants were screened for glaucoma and NA-AION using the RTVue-100 OCT, and also by independent clinical examination. For the RTVue-100 OCT measurements, the optic nerve head (ONH) scan and the macular ganglion cell complex (GCC) scan were applied. Subjects with possible optic neuropathy (as indicated by any of the scans and/or by the clinical examination) underwent a detailed clinical investigation to verify or exclude the disease. Of the 146 attendees, 133 participants (256 eyes) successfully underwent the RTVue-100 OCT measurements. Of these, six eyes (2.3%) had glaucoma and three eyes (1.2%) had partial optic atrophy due to earlier NA-AION. The retinal nerve fibre layer (RNFL) parameters (provided by the instrument software) had 99.2-99.6% specificity, 96.5-96.9% accuracy, and positive likelihood ratio (PLR) of 27.3-54.7, but only 11.1-22.2% sensitivity. Accuracy and PLR for the ONH parameters were <95% and <8.3, respectively. The GCC scan of the macula provided up to 95.9% specificity, 94.0% accuracy, 10.7 PLR and 44.4% sensitivity. During the screening of this Caucasian population with 3.5% prevalence of optic neuropathy due to glaucoma and NA-AION, the RTVue-100 OCT was found to be useful for screening, with both RNFL and GCC parameters providing high accuracy and PLR values >10.

摘要

本研究的目的是评估RTVue - 100傅里叶域光学相干断层扫描仪(RTVue - 100 OCT)在青光眼和非动脉炎性前部缺血性视神经病变(NA - AION)筛查中的效用。在一项非基于人群的预公布试验中,使用RTVue - 100 OCT并通过独立临床检查,对自我招募的白种人参与者进行青光眼和NA - AION筛查。对于RTVue - 100 OCT测量,应用了视神经乳头(ONH)扫描和黄斑神经节细胞复合体(GCC)扫描。有潜在视神经病变的受试者(由任何扫描和/或临床检查表明)接受详细的临床调查以证实或排除疾病。在146名参与者中,133名(256只眼)成功进行了RTVue - 100 OCT测量。其中,6只眼(2.3%)患有青光眼,3只眼(1.2%)因既往NA - AION导致部分视神经萎缩。视网膜神经纤维层(RNFL)参数(由仪器软件提供)的特异性为99.2 - 99.6%,准确性为96.5 - 96.9%,阳性似然比(PLR)为27.3 - 54.7,但敏感性仅为11.1 - 22.2%。ONH参数的准确性和PLR分别<95%和<8.3。黄斑的GCC扫描提供了高达95.9%的特异性、94.0%的准确性、10.7的PLR和44.4%的敏感性。在对因青光眼和NA - AION导致视神经病变患病率为3.5%的白种人群进行筛查期间,发现RTVue - 100 OCT对筛查有用,RNFL和GCC参数均提供了高准确性且PLR值>10。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验