Suppr超能文献

脑静脉和动脉的磁敏感加权成像(SWAN)与 TOF-MRA 的比较。

Susceptibility-weighted angiography (SWAN) of cerebral veins and arteries compared to TOF-MRA.

机构信息

Department of Neuroradiology, University Hospital Munich, Marchioninistrasse 15, 81377 München, Germany.

出版信息

Eur J Radiol. 2012 Jun;81(6):1238-45. doi: 10.1016/j.ejrad.2011.02.057. Epub 2011 Apr 5.

Abstract

PROBLEM

High resolution, non-contrast imaging of both cerebral veins and arteries by use of gradient echo T2 star weighted angiography (SWAN) is a new method for susceptibility-weighted imaging with short acquisition times. We assessed the potential of this sequence for the depiction of both cerebral veins and arteries.

METHODS

15 healthy volunteers were included in the study. MRI was performed on a 3T MR scanner using the following sequences: (1) a 3D multi-echo gradient echo T2 star weighted angiography (SWAN), (2) an arterial 3D TOF MR angiography and (3) a venous 2D TOF. With regard to the SWAN sequence, both MinIP and MIP images were reconstructed and systematically compared to MIP reconstructions of the artTOF and the venTOF. To suggest possible clinical implications of our findings, we additionally included two illustrative cases.

RESULTS

With regard to the visualization of the cerebral veins, the MinIP reconstructions of the SWAN sequence were considerably superior compared to the venTOF. Concerning the depiction of the main segments of the big cerebral arteries the value of the MIP reconstructions of the SWAN was comparable to that of the artTOF with limitations in the homogenity and in the depiction of smaller arteries.

CONCLUSIONS

SWAN allows for high-resolution visualization of both cerebral veins and arteries in one sequence without application of contrast agent and with significantly shortened scan time compared to the combined scan time of TOF-MRA and TOF-MRV. By use of either MinIP or MIP reconstructions, the arteries can be distinguished from the veins.

摘要

问题

利用梯度回波 T2 星加权血管造影术(SWAN)进行高分辨率、无需对比剂的脑静脉和动脉成像,是一种新的磁敏感加权成像方法,具有较短的采集时间。我们评估了该序列显示脑静脉和动脉的潜力。

方法

15 名健康志愿者纳入本研究。使用以下序列在 3T 磁共振扫描仪上进行 MRI:(1)三维多回波梯度回波 T2 星加权血管造影术(SWAN),(2)动脉三维时间飞跃磁共振血管造影术(artTOF)和(3)静脉二维时间飞跃磁共振血管造影术(venTOF)。对于 SWAN 序列,均重建 MinIP 和 MIP 图像,并与 artTOF 和 venTOF 的 MIP 重建进行系统比较。为了提示我们的发现可能具有临床意义,我们还纳入了两个说明性病例。

结果

在显示脑静脉方面,SWAN 序列的 MinIP 重建明显优于 venTOF。在显示大脑主要动脉段方面,SWAN 的 MIP 重建与 artTOF 的价值相当,但在均匀性和较小动脉的显示方面存在局限性。

结论

SWAN 允许在一个序列中进行高分辨率的脑静脉和动脉可视化,无需应用对比剂,与 artTOF 和 venTOF 的联合扫描时间相比,扫描时间显著缩短。通过使用 MinIP 或 MIP 重建,可以区分动脉和静脉。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验