人工泪液在干眼受试者中的视觉效果和停留时间。

Visual effect and residence time of artificial tears in dry eye subjects.

作者信息

Hall Jonathan Q, Ridder William H, Nguyen Andrew Loc, Paugh Jerry R

机构信息

Southern California College of Optometry, Fullerton, California 92831, USA.

出版信息

Optom Vis Sci. 2011 Jul;88(7):872-80. doi: 10.1097/OPX.0b013e31821b0b2c.

Abstract

PURPOSE

The purpose of this investigation was to examine the relationship between the visual effect (VE) and residence time (RT) of artificial tears (ATs) in dry eye subjects.

METHODS

The VEs and RTs were measured after administration of 25 μl of an AT into the inferior fornix of 18 dry eye subjects. The VE was investigated by measuring contrast sensitivity before and after AT administration. The return to baseline sensitivity (RTBS) was taken as the time it took to return to within 1 SD of baseline contrast sensitivity. RT was measured using fluorescent formulations and a scanning fluorometer.

RESULTS

No correlation was found between RTBS and RT for a low viscosity (saline-F) and a medium viscosity AT (CMC-F; p>0.05). There was a moderate correlation for a higher viscosity AT (PEG-F; p=0.03). For all solutions, RT was significantly longer than RTBS (p<0.001). There was a significant difference in RTBS between saline-F and PEG-F (p=0.002) but not between saline-F and CMC-F (p=0.87). There was a significant difference in RT between saline-F and both PEG-F and CMC-F (p<0.001 and p=0.018, respectively).

CONCLUSIONS

No correlation was found between RTBS and RT for saline-F or CMC-F (moderate correlation for PEG-F). These ATs are present on the eye for a significantly longer time than their adverse affect on vision. An ideal AT would result in minimal if any initial blur on instillation while remaining in the eye for an extended period of time.

摘要

目的

本研究旨在探讨干眼症患者中人工泪液(ATs)的视觉效果(VE)与停留时间(RT)之间的关系。

方法

向18名干眼症患者的下穹窿滴入25μl人工泪液后,测量其视觉效果和停留时间。通过测量人工泪液给药前后的对比敏感度来研究视觉效果。恢复到基线敏感度(RTBS)定义为恢复到基线对比敏感度标准差范围内所需的时间。使用荧光制剂和扫描荧光计测量停留时间。

结果

对于低粘度(生理盐水-F)和中粘度人工泪液(羧甲基纤维素-F;CMC-F),恢复到基线敏感度与停留时间之间未发现相关性(p>0.05)。对于较高粘度的人工泪液(聚乙二醇-F;PEG-F),两者存在中度相关性(p = 0.03)。对于所有溶液,停留时间均显著长于恢复到基线敏感度所需时间(p<0.001)。生理盐水-F和聚乙二醇-F之间的恢复到基线敏感度存在显著差异(p = 0.002),但生理盐水-F和羧甲基纤维素-F之间无显著差异(p = 0.87)。生理盐水-F与聚乙二醇-F和羧甲基纤维素-F的停留时间均存在显著差异(分别为p<0.001和p = 0.018)。

结论

生理盐水-F或羧甲基纤维素-F的恢复到基线敏感度与停留时间之间未发现相关性(聚乙二醇-F为中度相关性)。这些人工泪液在眼表停留的时间明显长于其对视力的不良影响持续的时间。理想的人工泪液在滴入时应产生最小的初始模糊(若有),同时能在眼内长时间留存。