Cell locomotion and chemotaxis are usually assayed by the Boyden chamber technique, in which the response is measured by microscopical counting of the cells migrated into a micropore filter. We report a simplified Boyden chamber method which utilizes myeloperoxidase (MPO) specific to neutrophilic and monocytic leukocytes. The chamber is incubated for a period long enough for the neutrophils to migrate through the first of two superimposed filters. The cells entering the second filter are then lysed and the released MPO activity is quantitated. Random migration, chemokinesis, and chemotaxis measurements of neutrophils were compared by the enzymatic and the conventional cell count methods. There was good agreement between the two methods (0.84 less than r less than 0.98). The intraassay precision of the enzymatic and the cell count methods was equal; the coefficients of variation were 14 and 15%, respectively. The enzymatic method provides a more objective, reliable, and rapid modification of the Boyden chamber assay for analysis of neutrophil chemotaxis.

摘要

细胞运动和趋化性通常通过博伊登室技术进行测定,其中通过显微镜计数迁移到微孔滤膜中的细胞来测量反应。我们报告了一种简化的博伊登室方法,该方法利用嗜中性和单核白细胞特有的髓过氧化物酶(MPO)。将室孵育足够长的时间,以使嗜中性粒细胞迁移穿过两个叠加滤膜中的第一个。然后将进入第二个滤膜的细胞裂解,并对释放的MPO活性进行定量。通过酶法和传统细胞计数法比较了嗜中性粒细胞的随机迁移、化学增活现象和趋化性测量。两种方法之间具有良好的一致性(0.84<r<0.98)。酶法和细胞计数法的测定内精密度相同;变异系数分别为14%和15%。酶法为分析嗜中性粒细胞趋化性的博伊登室测定提供了一种更客观、可靠且快速的改进方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验