Suppr超能文献

静息心率变异性的短期稳定性:体位和性别影响。

Short-term stability of resting heart rate variability: influence of position and gender.

机构信息

Institute of Sport and Exercise Science, James Cook University, Townsville, Queensland 4811, Australia.

出版信息

Appl Physiol Nutr Metab. 2011 Apr;36(2):210-8. doi: 10.1139/h10-103.

Abstract

Heart rate variability (HRV) is utilized within laboratory and clinical settings as a noninvasive indicator of cardiac autonomic modulation. Past research has utilized a wide variety of resting methodologies and, as such, it is difficult to draw conclusions on the nature of HRV from different studies. Therefore, the current study aimed to assess the short-term stability of resting HRV during a 40-min resting trial and the impact of body position and gender on this short-term stability. Resting HRV was determined from 40-min trials in 3 standard positions (supine, seated, and standing) for healthy males (n = 14) and females (n = 16). Time-domain, geometric, and frequency-domain measures of resting HRV were examined during consecutive 10-min segments using a 3-way ANOVA (time × position × gender) and Tukeys' post-hoc tests with reproducibility assessed by intraclass correlation coefficients (ICC) and coefficients of variation. During rest, most HRV measures fluctuated over time, were greater in the supine compared to the standing position, and were greater for males compared with females. Variables that reflected primarily vagal modulations of heart rate remained stable, whereas other HRV measures varied over time. The majority of HRV variables exhibited substantial to excellent short-term reproducibility (ICC > 0.6) with time-domain and geometric measures of HRV demonstrating greater values compared with frequency-domain parameters. Based on the current results, the recording and analysis of HRV at 0-10 min of rest was recommended as a standardized protocol for the assessment of resting HRV in any standard position for either gender during laboratory and (or) clinical settings.

摘要

心率变异性(HRV)在实验室和临床环境中被用作心脏自主调节的非侵入性指标。过去的研究使用了各种各样的静息方法,因此,很难从不同的研究中得出关于 HRV 本质的结论。因此,本研究旨在评估 40 分钟静息试验中静息 HRV 的短期稳定性,以及体位和性别对这种短期稳定性的影响。健康男性(n = 14)和女性(n = 16)在 3 个标准体位(仰卧位、坐位和站立位)下进行 40 分钟试验,确定静息 HRV。使用 3 因素方差分析(时间×体位×性别)和 Tukey 事后检验,在连续 10 分钟的片段中检查静息 HRV 的时域、几何和频域指标,用组内相关系数(ICC)和变异系数评估重复性。在休息期间,大多数 HRV 指标随时间波动,仰卧位时比站立位时更大,男性比女性时更大。反映心率主要受迷走神经调节的变量保持稳定,而其他 HRV 指标随时间变化。大多数 HRV 变量表现出较好的短期可重复性(ICC > 0.6),时域和几何 HRV 测量值比频域参数值更大。根据目前的结果,建议在 0-10 分钟的休息时间内记录和分析 HRV,作为在实验室和(或)临床环境中评估任何标准体位下男女静息 HRV 的标准化方案。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验