Suppr超能文献

健康受试者时域和谱域光学相干断层扫描测量的视网膜厚度的日间变化。

Diurnal variation of retina thickness measured with time domain and spectral domain optical coherence tomography in healthy subjects.

机构信息

Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Republic of Korea.

出版信息

Invest Ophthalmol Vis Sci. 2011 Aug 17;52(9):6497-500. doi: 10.1167/iovs.11-7403.

Abstract

PURPOSE. To investigate diurnal variations in macular thickness and total macular volume using time domain optical coherence tomography (TD-OCT) and spectral domain OCT (SD-OCT) in healthy subjects. METHODS. Data were derived from 52 eyes of 52 healthy subjects. Macular thickness, macular volume was measured by using TD-OCT and SD-OCT at 8 AM and 6 PM. RESULTS. Comparing TD-OCT measurements, retinal thickness was significantly greater in the afternoon than in the morning in 3 of 9 grid subfields: central macular thickness (CMT) (194 vs. 190 μm; P = 0.006), superior inner area (276 vs. 273 μm; P = 0.010), and temporal inner area (261 vs. 258 μm; P = 0.006). In SD-OCT measurements, CMT, pericentral macular thickness, and macular volume did not differ significantly between the morning and the afternoon. Comparing the absolute variation in the parameters measured by the two devices, central macular thickness and temporal inner area thickness differed significantly (P = 0.015, P = 0.029), whereas other area thicknesses and macular volumes did not. Comparing the relative variation of the two devices, CMT and temporal inner area thickness differed significantly (P = 0.014, P = 0.027), whereas other area thicknesses and macular volume showed no significant difference. The moduli of variations for CMT, macular volume, and pericentral macular thickness were significantly lower using SD-OCT than using TD-OCT. CONCLUSIONS. The diurnal variation of the TD-OCT measurements was likely due to the limited repeatability of the device rather than to tissue variation. Diurnal variation was not found using SD-OCT, which has better repeatability.

摘要

目的

使用时域光相干断层扫描(TD-OCT)和谱域 OCT(SD-OCT)研究健康受试者的黄斑厚度和总黄斑体积的日间变化。

方法

资料来源于 52 名健康受试者的 52 只眼。分别于上午 8 点和下午 6 点使用 TD-OCT 和 SD-OCT 测量黄斑厚度和黄斑体积。

结果

与 TD-OCT 测量结果比较,9 个网格分区中有 3 个分区的视网膜厚度在下午高于上午:中央黄斑厚度(CMT)(194 μm 比 190 μm;P = 0.006)、上内区(276 μm 比 273 μm;P = 0.010)和颞内区(261 μm 比 258 μm;P = 0.006)。在 SD-OCT 测量中,上午和下午的 CMT、近中心黄斑厚度和黄斑体积无显著差异。比较两种仪器测量参数的绝对变化,中央黄斑厚度和颞内区厚度差异显著(P = 0.015,P = 0.029),而其他区厚度和黄斑体积无显著差异。比较两种仪器相对变化,CMT 和颞内区厚度差异显著(P = 0.014,P = 0.027),而其他区厚度和黄斑体积无显著差异。CMT、黄斑体积和近中心黄斑厚度的变异系数使用 SD-OCT 时明显低于 TD-OCT。

结论

TD-OCT 测量的日间变化可能是由于仪器的可重复性有限,而不是组织变化所致。使用具有更好可重复性的 SD-OCT 未发现日间变化。