J Adhes Dent. 2012 Apr;14(2):137-45. doi: 10.3290/j.jad.a21854.
To evaluate whether Nd:YAG laser irradiation of etched and unetched dentin through an uncured adhesive affected the microtensile bond strength (µTBS).
Flat dentin surfaces were created in 19 extracted human third molars. Adper Single Bond (SB) adhesive was applied over etched (groups 1 to 3) or unetched dentin (groups 4 to 6). The dentin was then irradiated with a Nd:YAG laser through the uncured adhesive, using 0.75 or 1 W power settings, except for the control groups (groups 1 and 4). The adhesive was light cured and composite crowns were built up. After 24 h, the teeth were sectioned into beams, with cross-sectional areas of 0.49 mm2, and were stressed under tension. Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 5%). Dentin surfaces of fractured specimens and the interfaces of untested beams were observed under scanning electron microscopy (SEM).
Acid etching, laser irradiation, and their interaction significantly affected bonding (p < 0.05). Laser irradiation did not improve bonding of etched dentin to resin (p > 0.05). However, higher µTBS means were found on unetched lased dentin (groups 5 and 6), but only in comparison to group 4, where neither lasing nor etching was performed. Groups 4 to 6 showed the lowest µTBS means among all groups tested (p < 0.05). Laser irradiation did not change the characteristics of the hybrid layers created, while solidification globules were observed on lased dentin surfaces under SEM.
Laser irradiation of dentin through the uncured adhesive did not significantly improve the µTBS in comparison to the suggested manufacturer's technique.
评估通过未固化的黏合剂对酸蚀和未酸蚀牙本质进行钕:钇铝石榴石激光照射是否会影响微拉伸黏结强度(µTBS)。
在 19 颗离体的第三磨牙上制备平坦的牙本质表面。将 Adper Single Bond(SB)黏合剂应用于酸蚀牙本质(第 1 组至第 3 组)或未酸蚀牙本质(第 4 组至第 6 组)。然后,通过未固化的黏合剂用 0.75 或 1 W 的功率设置用 Nd:YAG 激光照射牙本质,除了对照组(第 1 组和第 4 组)。黏合剂被光固化并用复合冠修复。24 h 后,牙齿被切成束,横截面面积为 0.49 mm2,并在张力下受力。使用双因素方差分析和 Tukey 检验(α=5%)对数据进行统计分析。用扫描电子显微镜(SEM)观察断裂标本的牙本质表面和未经测试的梁的界面。
酸蚀、激光照射及其相互作用显著影响黏合(p<0.05)。激光照射并没有提高酸蚀牙本质与树脂的黏合(p>0.05)。然而,在未酸蚀的激光照射牙本质(第 5 组和第 6 组)上发现了更高的 µTBS 平均值,但仅与未进行激光照射和酸蚀的第 4 组相比。在所有测试的组中,第 4 组至第 6 组的 µTBS 平均值最低(p<0.05)。激光照射没有改变形成的混合层的特性,但在 SEM 下观察到激光照射牙本质表面有凝固小球。
与推荐的制造商技术相比,通过未固化的黏合剂对牙本质进行激光照射并不能显著提高 µTBS。