Division of Adolescent Medicine, Department of Pediatrics, School of Medicine, University of California, San Francisco, 513 Parnassus Avenue, San Francisco, CA 94143, USA.
Cytokine. 2011 Nov;56(2):430-4. doi: 10.1016/j.cyto.2011.06.011. Epub 2011 Jul 18.
The interlaboratory reproducibility of cytokine measurements from cervicovaginal samples by Luminex has not been reported. Using cervicovaginal lavage specimens collected on three study days from 12 women participating in a Phase I microbicide study, we measured a panel of eight cytokines in three independent laboratories. Four (IFN-γ, IL-10, IL-17, and TNF) were below the limit of detection in the majority (85%) of samples in either two or all three laboratories, an observation that may guide analyte selection for future studies. Good interlaboratory agreement (intraclass correlation coefficient, r>0.7) in absolute levels was observed for IL-1β, IL-6, and IL-8, while poor agreement was seen for IFN-α2 (r=0.47). When considering within-subject change from baseline (pre-product, at study-day 0) to either post-product visit (study-days 7 and 14), IL-1β and IL-6 exhibited good interlaboratory agreement (r>0.7), while IFN-α2 and IL-8 did not. Future studies addressing the clinical utility of specific biomarkers of inflammation for microbicide trials should consider reproducibility in the context of defining biologically meaningful thresholds of change for candidate biomarkers, ensuring that such change can be reliably distinguished from background variability.
尚未报道通过 Luminex 对宫颈阴道样本中的细胞因子测量进行实验室间可重复性研究。我们使用参与 I 期杀微生物剂研究的 12 名女性在 3 个研究日采集的宫颈阴道灌洗液标本,在 3 个独立实验室中测量了 8 种细胞因子的一组指标。在两个或所有三个实验室中,有 4 种(IFN-γ、IL-10、IL-17 和 TNF)在大多数(85%)样本中低于检测限,这一观察结果可能为未来的研究指导分析物的选择。对于 IL-1β、IL-6 和 IL-8,观察到良好的实验室间一致性(组内相关系数,r>0.7),而 IFN-α2 的一致性较差(r=0.47)。当考虑从基线(产品前,在研究第 0 天)到产品后访视(第 7 和 14 天)的个体内变化时,IL-1β 和 IL-6 表现出良好的实验室间一致性(r>0.7),而 IFN-α2 和 IL-8 则没有。未来研究应考虑在确定候选生物标志物的生物学上有意义的变化阈值的背景下,解决炎症特定生物标志物在杀微生物剂试验中的临床实用性,确保可以从背景变异性中可靠地区分这种变化。