6 个视网膜像质的可察觉差异仅在 1 行视力:定量评估 20/20 视力的快乐与不快乐的患者。

Six just-noticeable differences in retinal image quality in 1 line of visual acuity: toward quantification of happy versus unhappy patients with 20/20 acuity.

机构信息

College of Optometry, University of Houston, Houston, Texas 77204-2020, USA.

出版信息

J Cataract Refract Surg. 2011 Aug;37(8):1523-9. doi: 10.1016/j.jcrs.2011.02.034.

Abstract

PURPOSE

To determine the number of just-noticeable differences in wavefront blur necessary to induce a 1-line loss of corrected distance visual acuity (CDVA).

SETTING

Visual Optics Institute, College of Optometry, University of Houston, Houston, Texas, USA.

DESIGN

Evidence-based manuscript.

METHODS

The 3.0 mm wavefront error of a well-corrected average eye was scaled to yield 9 small steps of blur quantified in units of log visual Strehl (logVS). For each logVS value, 10 unique 3-line acuity charts were generated. Using a temporal forced-choice paradigm, subjects compared each test chart to a reference acuity chart and indicated which chart was blurrier. The difference between 80% and 50% on the psychometric function defined a just-noticeable difference. The CDVA was measured up to fifth-letter miss for several aberrated logMAR charts for 6 logVS values. The number of just-noticeable differences necessary to lose 1 line of acuity was defined as the change in logVS necessary to lose 1 line of acuity divided by the 1 just-noticeable difference in logVS.

RESULTS

Linear regression showed that logVS = -2.98 × (logMAR acuity) - 0.31 (R(2) = 0.961). The mean just-noticeable difference was 0.049 logVS ± 0.012 (SD), resulting in a mean of 6.1 just-noticeable differences per line of logMAR acuity.

CONCLUSIONS

The retinal image quality metric logVS was highly correlated with logMAR acuity. The 6 just-noticeable differences in logVS before 1 line of acuity was lost may provide an objective explanation for the distinction between patients with 20/20 CDVA who are happy and patients with 20/20 CDVA who are unhappy and other aberration-related clinical complaints when acuity is near normal.

摘要

目的

确定引起矫正距离视力(CDVA)损失 1 行所需的波前模糊的可觉察差异数量。

设置

美国德克萨斯州休斯顿休斯顿大学视光学研究所,视光学院。

设计

基于证据的手稿。

方法

将一只矫正良好的平均眼的 3.0 毫米波前误差缩放到产生 9 个小的模糊度单位为对数视觉斯特尔(logVS)的步骤。对于每个 logVS 值,生成 10 个独特的 3 行视力表。使用时间强制选择范式,受测者将每个测试图表与参考视力图表进行比较,并指出哪个图表更模糊。心理功能曲线 80%和 50%之间的差异定义为可觉察差异。对于 6 个 logVS 值的几个偏差 logMAR 图表,测量了直至第五个字母错过的 CDVA。为了失去 1 行视力,需要的可觉察差异数量定义为失去 1 行视力所需的 logVS 变化除以 logVS 中的 1 个可觉察差异。

结果

线性回归表明 logVS = -2.98 ×(logMAR 视力)-0.31(R²= 0.961)。平均可觉察差异为 0.049 logVS ± 0.012(SD),导致每一行 logMAR 视力丧失 6.1 个可觉察差异。

结论

视网膜图像质量指标 logVS 与 logMAR 视力高度相关。在失去 1 行视力之前,6 个可觉察差异的 logVS 可能为区分视力接近正常时具有 20/20 CDVA 的快乐患者和具有 20/20 CDVA 的不快乐患者以及其他与像差相关的临床投诉提供客观解释。

相似文献

7
Retinal image quality during accommodation.调节时的视网膜像质。
Ophthalmic Physiol Opt. 2013 Jul;33(4):497-507. doi: 10.1111/opo.12075.

引用本文的文献

本文引用的文献

2
Image metrics for predicting subjective image quality.用于预测主观图像质量的图像指标。
Optom Vis Sci. 2005 May;82(5):358-369. doi: 10.1097/01.OPX.0000162647.80768.7F.
3
Foveal blur discrimination of the human eye.人眼的中央凹模糊辨别
Ophthalmic Physiol Opt. 2005 Jan;25(1):45-51. doi: 10.1111/j.1475-1313.2004.00250.x.
9
Measurement of visual acuity; a critical review.视力测量;批判性综述。
AMA Arch Ophthalmol. 1951 Jun;45(6):704-25. doi: 10.1001/archopht.1951.01700010719013.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验