Suppr超能文献

评估一种新的超声参考图谱在类风湿关节炎患者滑膜炎评分中的内部和外部评分者间可靠性。

Examination of intra and interrater reliability with a new ultrasonographic reference atlas for scoring of synovitis in patients with rheumatoid arthritis.

机构信息

Department of Rheumatology, Diakonhjemmet Hospital, Box 23, Vinderen, N-0319 Oslo, Norway.

出版信息

Ann Rheum Dis. 2011 Nov;70(11):1995-8. doi: 10.1136/ard.2011.152926. Epub 2011 Jul 22.

Abstract

OBJECTIVE

Synovitis in patients with rheumatoid arthritis (RA) may be scored semiquantitatively (0-3) for B-mode (BM) and power Doppler (PD) ultrasonography. The objective was to assess the reliability of BM and PD examinations with a novel ultrasonographic atlas as reference.

METHODS

Representative ultrasound images (including scores 0-3) of BM and PD from 24 different joints were collected to develop an ultrasonographic atlas. Ten RA patients were assessed twice by five rheumatologists performing BM and PD scoring (0-3) of 16 joints bilaterally (metacarpophalangeal 1-5, wrist (radiocarpal, intercarpal, radioulnar), elbow, knee, talocrural and metatarsophalangeal 1-5), with the novel ultrasonographic atlas as a reference.

RESULTS

The median (range) percentages of exact agreements for BM/PD assessments were 73.1 (70.3-80.6)/83.7 (76.7-87.6) and for close agreement 98.1 (96.2-99.7)/98.0 (96.8-98.4) with weighted κ values of median (range) 0.77 (0.70-0.83) for BM and 0.83 (0.73-0.86) for PD. The intrarater intraclass correlation coefficients (ICC) for BM/PD scores were 0.95 (0.93-0.99)/0.97 (0.95-0.99) and interrater ICC were 0.95 (0.86-0.99)/0.97 (0.94-1.00). Scoring of 32 joints was completed in median 15 min (range 12-20).

CONCLUSION

With the use of an ultrasonographic atlas as reference high intra and interrater reliability was found for BM and PD scoring. This novel atlas may be a useful resource in clinical practice and research.

摘要

目的

类风湿关节炎(RA)患者的滑膜炎可通过 B 型(BM)和能量多普勒(PD)超声半定量评分(0-3)进行评分。目的是评估使用新型超声图谱作为参考时 BM 和 PD 检查的可靠性。

方法

收集 24 个不同关节的代表性超声图像(包括 0-3 分),以开发超声图谱。10 名 RA 患者由 5 名风湿病学家进行两次评估,对双侧 16 个关节(掌指 1-5、腕(桡腕、腕间、桡尺)、肘、膝、跗跖和跖趾 1-5)进行 BM 和 PD 评分(0-3),以新型超声图谱作为参考。

结果

BM/PD 评估的精确一致百分比中位数(范围)分别为 73.1(70.3-80.6)/83.7(76.7-87.6)和接近一致的 98.1(96.2-99.7)/98.0(96.8-98.4),加权 κ 值中位数(范围)分别为 0.77(0.70-0.83)和 0.83(0.73-0.86)。BM/PD 评分的组内 ICC 为 0.95(0.93-0.99)/0.97(0.95-0.99),组间 ICC 为 0.95(0.86-0.99)/0.97(0.94-1.00)。中位数 15 分钟(范围 12-20 分钟)即可完成 32 个关节的评分。

结论

使用超声图谱作为参考,发现 BM 和 PD 评分具有较高的组内和组间可靠性。该新型图谱在临床实践和研究中可能是一种有用的资源。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验