Met-enkephalin can be rapidly separated with high recovery from leu-enkephalin, beta-endorphin, and enkephalin metabolites by high-pressure liquid chromatography on a Dupont SCX column. The technique permits separation of endogenous enkephalins from brain extracts for measurement by opiate-receptor binding assay, immunoassay, or for study of the incorporation of radiolabeled amino acids into enkephalin. Using this technique, met-enkephalin was separated from striatal extracts of rats killed by focused microwave irradiation and quantitated by the opiate-receptor binding assay. The concentration of met-enkephalin in the column eluate was 1.3 micron/g tissue. This value is comparable to that obtained by radioimmunoassay without purification of the extracts.
通过在杜邦SCX柱上进行高压液相色谱法,甲硫氨酸脑啡肽可以与亮氨酸脑啡肽、β-内啡肽及脑啡肽代谢产物快速分离,且回收率高。该技术能够从脑提取物中分离内源性脑啡肽,用于通过阿片受体结合测定、免疫测定进行测量,或用于研究放射性标记氨基酸掺入脑啡肽的情况。利用该技术,从聚焦微波辐射处死的大鼠纹状体提取物中分离出甲硫氨酸脑啡肽,并通过阿片受体结合测定进行定量。柱洗脱液中甲硫氨酸脑啡肽的浓度为1.3微克/克组织。该值与未经提取物纯化的放射免疫测定法所获得的值相当。