Suppr超能文献

Hemodynamic effects of negative-pressure ventilation in patients with COPD.

作者信息

Ambrosino N, Cobelli F, Torbicki A, Opasich C, Pozzoli M, Fracchia C, Rampulla C

机构信息

Clinica del Lavoro Foundation, Care and Research Center, Montescano, Italy.

出版信息

Chest. 1990 Apr;97(4):850-6. doi: 10.1378/chest.97.4.850.

Abstract

In order to evaluate the hemodynamic effects of INPV, eight patients with COPD (FEV1/FVC, 54 +/- 6 percent; mean +/- SD), respiratory failure (PaO2, 52 +/- 6 mm Hg; PaCO2, 56 +/- 4 mm Hg), and clinical signs of inspiratory muscle fatigue underwent right cardiac catheterization while performing 20 minutes of INPV by a cuirass ventilator at a pressure (-20 to -40 cm H2O) able to reduce the diaphragmatic electromyographic activity. Patients showed a mild basal pulmonary artery hypertension. During INPV, no changes in the mean values of HR (from 79 +/- 20 to 80 +/- 18 beats per minute), systolic BP (141 +/- 19 to 139 +/- 16 mm Hg), CO (5.2 +/- 0.8 to 5.1 +/- 1.3 L/min), mean PAP (23.8 +/- 3.8 to 23.9 +/- 4.4 mm Hg), RAP (4.3 +/- 2.6 to 5.5 +/- 2.5 mm Hg), PWP (10.3 +/- 4.5 to 9.4 +/- 2.9 mm Hg), TPR (369 +/- 76 to 392 +/- 124 dynes.s.cm-5), and PVR (199 +/- 51 to 233 +/- 94 dynes.s.cm-5) were observed. Direct systemic BP monitoring could be performed in six patients. During INPV, three patients showed "pulsus paradoxus," as assessed by an inspiratory fall in systolic BP of 11, 13, and 20 mm Hg, respectively. We conclude that INPV by cuirass ventilator does not induce adverse hemodynamic effects in patients with COPD who have pulmonary artery hypertension.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验