Liu Yanqin, Wang Hao, Yang Hongmei, Shi Hailiang, Guo Qilei
Haidian District Institute of Products Quality Supervision and Inspection, Beijing 100094, China.
Se Pu. 2011 May;29(5):458-61. doi: 10.3724/sp.j.1123.2011.00458.
An analytical method based on high performance liquid chromatography with a diode array detector (HPLC-DAD) has been established for the simultaneous determination of 3 benzalkonium chloride homologs (n-C12H25-C9H13NCl, n-C14H29-C9H13NCl, n-C16,H33-C9H13NCl) in cosmetics. The sample was extracted with methanol (including 0.5% formic acid) under ultrasonic operation, the HPLC separation was carried out on a CAPCELL PAK SCX column (250 mm x 4.6 mm, 5 microm), the mobile phases were 40 mmol/L ammonium acetate solution (including 0.1% triethylamine) and acetonitrile with gradient elution, the flow rate was 1.0 mL/min, the detection wavelength was 260 nm, the column temperature was 25 degrees C, and the injection volume was 20 microL. The limit of detection was 50.0 mg/kg and the quantitation limit was 200.0 mg/kg for 3 benzalkonium chloride homologs in cosmetics. The linear plots were obtained between 5.0 mg/L and 3000.0 mg/L. Overall recoveries were between 92.5% and 102.1% with the relative standard deviations (RSDs) between 3.81% and 6.66%. The method is simple, rapid, accurate and suitable for the determination of 3 benzalkonium chloride homologs in cosmetics.
建立了一种基于高效液相色谱-二极管阵列检测器(HPLC-DAD)的分析方法,用于同时测定化妆品中的3种苯扎氯铵同系物(正十二烷基苄基二甲基氯化铵、正十四烷基苄基二甲基氯化铵、正十六烷基苄基二甲基氯化铵)。样品在超声作用下用甲醇(含0.5%甲酸)萃取,HPLC分离在CAPCELL PAK SCX柱(250 mm×4.6 mm,5μm)上进行,流动相为40 mmol/L醋酸铵溶液(含0.1%三乙胺)和乙腈,梯度洗脱,流速为1.0 mL/min,检测波长为260 nm,柱温为25℃,进样量为20μL。化妆品中3种苯扎氯铵同系物的检出限为50.0 mg/kg,定量限为200.0 mg/kg。在5.0 mg/L至3000.0 mg/L之间获得线性图。总回收率在92.5%至102.1%之间,相对标准偏差(RSD)在3.81%至6.66%之间。该方法简便、快速、准确,适用于化妆品中3种苯扎氯铵同系物的测定。