A histological comparison in the dog of porous-coated vs. threaded dental implants.

作者信息

Deporter D A, Watson P A, Pilliar R M, Chipman M L, Valiquette N

机构信息

Medical Research Council Program in Dental Implantology, Faculty of Dentistry, University of Toronto, Ontario.

出版信息

J Dent Res. 1990 May;69(5):1138-45. doi: 10.1177/00220345900690050401.

Abstract

The histological findings of an 18-month trial, in the dog of a partially porous-coated endosseous dental implant made of Ti-6Al-4V, with a truncated conical shape, are described and compared with those for a cylindrical, threaded, endosseous implant made of commercially pure Ti. Six beagle dogs each received two porous-coated implants on one side of the mandible and two threaded implants on the contralateral side. Each set of two implants supported a two-unit fixed bridge for an 18-month functional period. Methylmethacrylate sections of both the buccolingual and mesiodistal aspects of each implant were examined qualitatively and by computer-assisted morphometry. The morphometric measurements were used for determination of the length of implant surface in direct contact with bone on each aspect of each implant. The data were expressed both as an absolute length and as a fraction of the maximum length available for contact (contact length fraction or CLF). On the buccal and lingual aspects of the implants, both the absolute lengths and CLF were significantly smaller for the porous-coated design. For the mesial and distal aspects, the absolute lengths and CLF were less for the porous-coated design, but the differences were not significant. However, when the absolute contact length was related to the corresponding vertical bone height, significant differences were observed, the absolute contact length being greater for any given bone height for the porous-coated design. Taken together, the data suggest that shorter implants may be used with the porous-coated design.

摘要

描述了一项为期18个月的试验组织学结果,该试验在犬类中进行,使用的是由Ti-6Al-4V制成的部分多孔涂层骨内牙种植体,呈截头圆锥形,并将其与由商业纯钛制成的圆柱形、带螺纹的骨内种植体的结果进行比较。六只比格犬在下颌骨一侧各植入两颗多孔涂层种植体,在对侧各植入两颗带螺纹的种植体。每组两颗种植体支撑一个双单位固定桥,为期18个月的功能期。对每个种植体的颊舌侧和近远中侧的甲基丙烯酸甲酯切片进行定性检查和计算机辅助形态测量。形态测量用于确定每个种植体各方面与骨直接接触的种植体表面长度。数据以绝对长度和可接触的最大长度的分数(接触长度分数或CLF)表示。在种植体的颊侧和舌侧,多孔涂层设计的绝对长度和CLF均显著较小。对于近中侧和远中侧,多孔涂层设计的绝对长度和CLF较小,但差异不显著。然而,当绝对接触长度与相应的垂直骨高度相关时,观察到显著差异,对于任何给定的骨高度,多孔涂层设计的绝对接触长度更大。综合来看,数据表明多孔涂层设计可能可以使用更短的种植体。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验