Suppr超能文献

体外全香烟烟雾暴露系统的评估:博尔格瓦特RM20S八注射器吸烟机。

Assessment of an in vitro whole cigarette smoke exposure system: The Borgwaldt RM20S 8-syringe smoking machine.

作者信息

Adamson Jason, Azzopardi David, Errington Graham, Dickens Colin, McAughey John, Gaça Marianna D

机构信息

British American Tobacco, Group R&D, Regents Park Road, Southampton, SO15 8TL, UK.

出版信息

Chem Cent J. 2011 Aug 26;5:50. doi: 10.1186/1752-153X-5-50.

Abstract

BACKGROUND

There have been many recent developments of in vitro cigarette smoke systems closely replicating in vivo exposures. The Borgwaldt RM20S smoking machine (RM20S) enables the serial dilution and delivery of cigarette smoke to exposure chambers for in vitro analyses. In this study we have demonstrated reliability and robustness testing of the RM20S in delivering smoke to in vitro cultures using an in-house designed whole smoke exposure chamber.

RESULTS

The syringe precision and accuracy of smoke dose generated by the RM20S was assessed using a methane gas standard and resulted in a repeatability error of ≤9%. Differential electrical mobility particle spectrometry (DMS) measured smoke particles generated from reference 3R4F cigarettes at points along the RM20S. 53% ± 5.9% of particles by mass reached the chamber, the remainder deposited in the syringe or connecting tubing and ~16% deposited in the chamber. Spectrofluorometric quantification of particle deposition within chambers indicated a positive correlation between smoke concentration and particle deposition. In vitro air-liquid interface (ALI) cultures (H292 lung epithelial cells), exposed to whole smoke (1:60 dilution (smoke:air, equivalent to ~5 μg/cm2)) demonstrated uniform smoke delivery within the chamber.

CONCLUSIONS

These results suggest this smoke exposure system is a reliable and repeatable method of generating and exposing ALI in vitro cultures to cigarette smoke. This system will enable the evaluation of future tobacco products and individual components of cigarette smoke and may be used as an alternative in vitro tool for evaluating other aerosols and gaseous mixtures such as air pollutants, inhaled pharmaceuticals and cosmetics.

摘要

背景

近期出现了许多能紧密模拟体内暴露情况的体外香烟烟雾系统。博格瓦特RM20S吸烟机(RM20S)可对香烟烟雾进行连续稀释,并将其输送至暴露舱用于体外分析。在本研究中,我们使用自行设计的全烟雾暴露舱,对RM20S向体外培养物输送烟雾的可靠性和稳健性进行了测试。

结果

使用甲烷气体标准评估了RM20S产生烟雾剂量的注射器精度和准确性,重复性误差≤9%。采用差分电迁移率颗粒光谱法(DMS)在RM20S沿线各点测量了参比3R4F香烟产生的烟雾颗粒。按质量计,53%±5.9%的颗粒进入了舱室,其余颗粒沉积在注射器或连接管中,约16%沉积在舱室内。对舱室内颗粒沉积进行的荧光光谱定量分析表明,烟雾浓度与颗粒沉积之间呈正相关。体外气液界面(ALI)培养物(H292肺上皮细胞)暴露于全烟雾(1:60稀释(烟雾:空气,相当于约5μg/cm²))时,在舱室内实现了均匀的烟雾输送。

结论

这些结果表明,该烟雾暴露系统是一种可靠且可重复的方法,可用于生成香烟烟雾并将ALI体外培养物暴露于其中。该系统将能够评估未来的烟草产品以及香烟烟雾的各个成分,还可作为一种体外工具,用于评估其他气溶胶和气体混合物,如空气污染物、吸入性药物和化妆品。