Suppr超能文献

Observer variability in echo-Doppler measurements of portal flow in cirrhotic patients and normal volunteers.

作者信息

Sabbá C, Weltin G G, Cicchetti D V, Ferraioli G, Taylor K J, Nakamura T, Moriyasu F, Groszmann R J

机构信息

Department of Diagnostic Radiology, Yale University, New Haven, Connecticut.

出版信息

Gastroenterology. 1990 Jun;98(6):1603-11. doi: 10.1016/0016-5085(90)91097-p.

Abstract

The intraobserver and interobserver variability in measuring the portal vein flow by the echo-Doppler technique was evaluated in a blind controlled study. A total of 22 cirrhotic patients and 14 normal volunteers were examined by two skilled operators using duplex Doppler within a period of 1-3 mo (6 cirrhotics and 7 normal volunteers by both observers). Area, mean velocity, and flow were measured (4 measurements: A, B on day 1; C, D on day 2). The intraclass correlation coefficient was used to assess both the statistical and clinical significance of intraobserver and interobserver agreement for the measurements of these three parameters. The level of intraobserver agreement for each parameter on normal subjects and cirrhotics was obtained from the two measurements on the same day and from the two measurements at the same time on consecutive days. Overall agreement between the four measurements was also calculated. Levels of interobserver agreement were obtained by calculating separately the intraclass correlation coefficient from each of the four pairs by measurements made on the same subject by the two observers over the same period of 2 days. The coefficient of variation was also used to compare the variability in these measurements. Overall, intraobserver agreement on normal subjects varied from good to excellent for observer 1, and from fair to good for observer 2. On cirrhotic patients, observer 1 was excellent at all times for all parameters. Observer 2 had lower intraclass correlation coefficient values, especially for velocity on consecutive days. For the best of the two observers on the portal flow, the coefficient of variation in cirrhotic patients ranged from 2%-30% with a mean +/- SEM of 12% +/- 4%. No acceptable interobserver agreement was found between the two observers in either of the two samples of subjects. These results support the use of this technique mainly for the determination of rapid and large changes in portal hemodynamics within a short period of time. The technique seems to have low precision in monitoring chronic changes in portal hemodynamics.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验