Department of Orthopedic and Trauma Surgery, Tehran University of Medical Sciences, Tehran, Iran.
Int Orthop. 2012 Apr;36(4):839-44. doi: 10.1007/s00264-011-1343-2. Epub 2011 Sep 1.
Complex distal humerus fractures are difficult to fix by conventional methods, especially in comminuted low distal humerus fractures. We propose a technique using small diameter K-wires and a plate on the humeral shaft.
Between May 2007 and March 2009, 19 patients with poor bone quality showing comminuted or low distal humerus fractures involving the articular surface were referred to our institution and were primarily treated by this technique that we called "pin and plate fixation". We have reviewed all the cases treated by this method.
The average age was 46 years. All of the patients were followed up for a mean of 12 months and had a good range of motion (the average total arc of flexion-extension was 99°); the average Disabilities of the Arm, Shoulder and Hand (DASH) score was 18 points. The Mayo Elbow Performance Index was measured and the mean score was 88 in our patients.
In this study, a technique has been evaluated for the treatment of complex distal humerus fractures. We recommend this technique in comminuted, osteoporotic or low distal humerus fractures in which other fixation methods seem difficult or even impossible.
复杂的肱骨远端骨折难以通过常规方法固定,尤其是在粉碎性低肱骨远端骨折中。我们提出了一种使用小直径克氏针和肱骨骨干上的钢板的技术。
在 2007 年 5 月至 2009 年 3 月期间,19 名骨质量差、表现为粉碎性或累及关节面的低肱骨远端骨折的患者被转诊到我们的机构,并通过我们称之为“针和板固定”的技术进行了初步治疗。我们已经回顾了所有通过这种方法治疗的病例。
平均年龄为 46 岁。所有患者平均随访 12 个月,活动范围良好(平均屈伸总弧为 99°);平均上肢残疾量表(DASH)评分为 18 分。我们的患者中, Mayo 肘功能评分平均为 88 分。
在这项研究中,评估了一种治疗复杂肱骨远端骨折的技术。我们建议在粉碎性、骨质疏松或低肱骨远端骨折中使用这种技术,在这些骨折中,其他固定方法似乎困难甚至不可能。