Australian Dental Manufacturing, Brisbane, Qld., Australia.
Int Endod J. 2011 Dec;44(12):1162-9. doi: 10.1111/j.1365-2591.2011.01940.x. Epub 2011 Sep 8.
To investigate the chemical interaction of calcium hydroxide with the corticosteroid triamcinolone acetonide in Ledermix Paste and in Odontopaste, a new steroid/antibiotic paste.
Validated methods were developed to analyse the interaction of calcium hydroxide in two forms, Pulpdent Paste and calcium hydroxide powder, with triamcinolone acetonide within Odontopaste and Ledermix Paste. High-performance liquid chromatography (HPLC) was used to analyse the mixed samples of the pastes and calcium hydroxide. The concentration of triamcinolone acetonide within the pastes was determined over 0, 2, 6, 24 and 72-h time-points. All tests with the HPLC involved the testing of the standard with triplicate injections alongside the samples. All samples were tested in duplicate with each injected twice; therefore, four tests were performed for each investigation. Linearity, precision and specificity of the testing procedures and apparatus were validated. Descriptive statistics are provided.
In both pastes, there was a marked rapid destruction of the triamcinolone acetonide steroid upon mixing with calcium hydroxide. Odontopaste suffered a lower rate of destruction of the triamcinolone acetonide component than Ledermix Paste, but both pastes showed very similar degrees of steroid destruction after 72 h. When using calcium hydroxide powder with Ledermix Paste, the triamcinolone was destroyed entirely and immediately.
The addition of calcium hydroxide to Odontopaste or Ledermix Paste results in the rapid destruction of the steroid.
研究氢氧化钙在 Ledermix 糊剂和 Odontopaste(一种新型的类固醇/抗生素糊剂)中与皮质类固醇曲安奈德的化学相互作用。
开发了经过验证的方法来分析两种形式的氢氧化钙(Pulpden t Paste 和氢氧化钙粉末)与 Odontopaste 和 Ledermix 糊剂中的曲安奈德的相互作用。高效液相色谱法(HPLC)用于分析糊剂和氢氧化钙的混合样品。在 0、2、6、24 和 72 小时时间点测定糊剂中曲安奈德的浓度。所有 HPLC 测试均涉及用三倍进样标准品与样品一起测试。每个样品都进行了两次测试,因此每个研究进行了四次测试。验证了测试程序和仪器的线性、精密度和特异性。提供了描述性统计数据。
在两种糊剂中,与氢氧化钙混合后,曲安奈德类固醇迅速明显破坏。与 Ledermix 糊剂相比,Odontopaste 中曲安奈德成分的破坏速度较低,但两种糊剂在 72 小时后均显示出非常相似程度的类固醇破坏。当将氢氧化钙粉末与 Ledermix 糊剂一起使用时,曲安奈德会立即完全被破坏。
氢氧化钙的加入会导致 Odontopaste 或 Ledermix 糊剂中的类固醇迅速破坏。