使用库尔特VCS进行白细胞分类计数。

Use of Coulter VCS for differential leukocyte counts.

作者信息

Picard F, Terroux N, Levy J P

机构信息

Laboratoire Central d'Hématologie, Hôpital Cochin, Paris, France.

出版信息

Nouv Rev Fr Hematol (1978). 1990;32(3):211-6.

PMID:2216705
Abstract

The Coulter VCS is a tridimensional flow cytometer designed for differential leukocyte counting on the basis of cell volume, light scatter and conductivity. The VCS differential performed on 192 non-flagged samples was compared with the blood smear, taken as the reference method. A good correspondence was found between the two methods. Two hundred and seventy pathological samples were studied by both the VCS and the reference method: 219 samples with no anomalies other than quantitative changes and 51 with abnormal cells. 41% of the quantitative changes presented without any flag; 59% were flagged: either isolated X5 flags (30%) or other flags needing blood smear review (29%). Samples with abnormal cells (51) were detected with one or more flags: X3 + X6 in myelocytic disease X2 + X7 in lymphocytic disease. Only two (1 hairy cell leukemia, 1 lymphoma) were not flagged; however in these cases the abnormalities were revealed by the presence of either a striking neutropenia or a lymphocytosis. This corresponded to a false-negative rate of 0.4% in the group studied. Further studies were performed on patients with X5 flagging only. The VCS differential was compared to the optical differential as a reference method. There was a good relationship between the two methods; thus X5 flagging could be established without further slide review provided the numerical values were within the range valid for the laboratory. Thus, in our system of working, both VCS flags (except isolated X5) and laboratory performance limits were taken into account as regards the need for blood smear review. This resulted in a review rate of 15%.

摘要

库尔特VCS是一种三维流式细胞仪,设计用于基于细胞体积、光散射和电导率进行白细胞分类计数。将对192份无标记样本进行的VCS分类计数结果与作为参考方法的血涂片进行比较。发现两种方法之间具有良好的一致性。用VCS和参考方法对270份病理样本进行了研究:219份样本除数量变化外无其他异常,51份样本含有异常细胞。41%的数量变化未出现任何标记;59%被标记:要么是孤立的X5标记(30%),要么是需要复查血涂片的其他标记(29%)。含有异常细胞的样本(51份)通过一个或多个标记检测到:髓细胞疾病中为X3 + X6,淋巴细胞疾病中为X2 + X7。只有两份样本(1份毛细胞白血病,1份淋巴瘤)未被标记;然而,在这些病例中,异常情况通过显著的中性粒细胞减少或淋巴细胞增多得以揭示。在所研究的组中,这相当于假阴性率为0.4%。仅对出现X5标记的患者进行了进一步研究。将VCS分类计数结果与作为参考方法的光学分类计数结果进行比较。两种方法之间存在良好的相关性;因此,只要数值在实验室有效的范围内,无需进一步复查玻片即可确定X5标记。因此,在我们的工作系统中,在考虑是否需要复查血涂片时,兼顾了VCS标记(孤立的X5标记除外)和实验室性能限度。这导致复查率为15%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验